Ordering information
AC-DC Power Supplies Enclosed Type
PB
A
10
F
-O -O
5ꢀ 6
PBA10F
1ꢀ
2ꢀ
3ꢀ
4ꢀ
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-06-472
R
6Optional *5
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is acquired)
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer external-
ly
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
Aꢀhigher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
Cover is optional
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA10F-5
10
5V 2A
PBA10F-12
10.8
12V 0.9A
PBA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
PBA10F-5
PBA10F-12
PBA10F-24
(
)
3
*
VOLTAGE[V]
AC85 - 264 1 or DC110 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
f
(
(
)
)
ACIN 100V 0.30typ Io=100%
CURRENT[A]
ACIN 200V 0.20typ Io=100%
( )
50/60 47 - 440 or DC
FREQUENCY[Hz]
INPUT
ACIN 100V 74typ
ACIN 200V 74typ
76typ
76typ
77typ
77typ
EFFICIENCY[%]
(
(
)
)
ACIN 100V 15typ Io=100%
INRUSH CURRENT[A]
ACIN 200V 30typ Io=100%
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.15/0.30max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
5
12
24
CURRENT[A]
2
0.9
0.5
6
6
1
1
1
1
*
*
*
*
*
*
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
50max
48max
100max
120max
160max
150max
180max
120max
150max
48max
96max
150max
120max
160max
150max
180max
240max
290max
96max
0
to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0
to +50
C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50 60max
C
2
*
DRIFT[mV]
20max
(
,
)
200typ ACIN 100V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
)
(
,
20typ ACIN 100V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15
10.0 - 13.2
12.00 - 12.48
19.2 - 27.0
24.00 - 24.96
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V] 5.75 - 7.00
15.0 - 18.0
30.0 - 37.0
(
)
OPERATING INDICATION
REMOTE ON/OFF
LED Green
None
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
ISOLATION INPUT-FG
OUTPUT-FG
,
,
(
)
AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
(
)
,
(
),
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
REGULATIONS
,
,
,
,
CONDUCTED NOISE
HARMONIC ATTENUATOR Complies with IEC61000-3-2 Not built-in to active filter
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
7
(
)
*
4
*
(
) ( )
W H
X X
(
)
CASE SIZE/WEIGHT
COOLING METHOD
31 78 68mm [1.22 3.07 2.68 inches] without terminal block
Convection
D / 150g max with cover : 180g max
X
X
X
X
OTHERS
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
*5 Please contact us about safety approvals for the model with option.
*6 Please contact us about dynamic load and input response.
*7 Please contact us about class C.
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*
*
*
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.