5秒后页面跳转
PBA75F-36 PDF预览

PBA75F-36

更新时间: 2024-11-05 05:59:39
品牌 Logo 应用领域
XPPOWER /
页数 文件大小 规格书
5页 215K
描述
AC-DC Chassis Mount

PBA75F-36 数据手册

 浏览型号PBA75F-36的Datasheet PDF文件第2页浏览型号PBA75F-36的Datasheet PDF文件第3页浏览型号PBA75F-36的Datasheet PDF文件第4页浏览型号PBA75F-36的Datasheet PDF文件第5页 
AC-DC Chassis Mount  
50-150 Watts  
PBA Series  
TH E X P E R T S IN PO W E R  
Universal PFC Input  
Convection Cooled  
Low Profile <1U  
Adjustable Output Voltage  
Optional Remote On/Off  
Optional Din Rail Mount  
High Efficiency  
Specification  
Input  
General  
Efficiency  
Isolation  
Input Voltage  
85-264 VAC (120-370 VDC)  
85% typical  
50 VAC (70 VDC) (Optional, contact  
sales)  
3000 VAC Input to Output  
2000 VAC Input to Ground  
500 VAC Output to Ground  
Input Frequency  
Input Current  
47-63 Hz  
Switching Frequency  
Indications  
60-550 kHz PFC, 130kHz PWM  
Green LED for unit operating  
2/1 A max at 115/230 VAC  
20/40 A max at 115/230 VAC  
EN61000-3-2 compliant  
Inrush Current  
Power Factor  
Leakage Current  
0.75 mA max, optional 0.15 mA - add  
suffix “-G” to model numbers  
Environmental  
Operating  
Temperature  
-10 °C to +70 °C, see derating curve  
-20 °C to +75 °C  
Output  
Storage  
Temperature  
Output Voltage  
Output Voltage  
Adjustment  
3.3 VDC to 48 VDC  
+10/-15%  
Relative Humidity  
Shock  
20-90% non-condensing  
20 G 11 ms, onceeach x, y and z axis  
2 G 10-55Hz for 3 min periods for  
60 min along each x, y and z axis  
Output Voltage  
Set Point  
±3% Vnom  
Vibration  
Minimum Load  
Start-Up Time  
Drift  
No minimum load required  
350 ms typical  
EMC & Safety  
Emissions  
±0.6% max  
EN55022 Level B conducted  
EN55022 Level B radiated  
Line Regulation  
Load Regulation  
Hold-up Time  
±1% max  
ESD  
Susceptibility  
EN61000-4-2 Level 4  
EN61000-4-3 Level 3  
EN61000-4-4 Level 4  
±2% max  
15 ms typical  
Radiated  
Susceptibility  
Output Ripple & Noise •  
1% of Vn pk-pk  
operates at 120-140% of Vnom  
Overvoltage  
Protection  
EFT/Burst  
Surge  
EN61000-4-5 Level 3 line to line  
EN61000-4-5 Level 4 line to earth  
Overload Protection  
Operates at 105% of rated current,  
autorecovery  
Voltage dips and  
interruptions  
EN61000-4-11  
Remote ON/OFF  
Optional. Add suffix “-R” to model  
number  
Safety Approvals  
UL60950, CSA 60950  
EN60950, EN50178  
www.xpplc.com  
sales@xpplc.com  

与PBA75F-36相关器件

型号 品牌 获取价格 描述 数据表
PBA75F-3R3 RSG

获取价格

Unit type
PBA75F-48 XPPOWER

获取价格

AC-DC Chassis Mount
PBA75F-48 RSG

获取价格

Unit type
PBA75F-48-N COSEL

获取价格

AC-DC Regulated Power Supply Module, 76.8W