UTZ-SC0331_2
2012/10/02
]
Violet Laser Diode
Engineering Sample
NDV4916E
• Optical Output Power: CW120mW
• Peak Wavelength: 410-420nm
Outline Dimension
ꢀFeatures
Unit (mm)
Φ
Φ
• Can Type: φ 5.6 Floating Mounted with Photo Diode and Zener Diode
(90°)
Emitting Point
(0.4)
ꢀ
Absolute Maximum Ratings
Absolute Maximum
Ratings
1.0±0.1
Item
Symbol
Unit
Z+
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Po
Ir (LD)
Vr (PD)
Tstg
140
85
mW
Φ
Φ
4.2±0.2
3.55±0.1
mA
V
Emitting Point
5
Reference Plane
Storage Temperature
-40 ~ 85
-10 ~ 30
°C
°C
Operating Case Temperature
Tc
4×Φ 0.43±0.08
(Tc=25°C)
ꢀ
Initial Electrical/Optical Characteristics
3
Item
Condition Symbol Min
Typ.
Max
Unit
mW
nm
mA
mA
W/A
V
X+
1
2
Optical Output Power
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
CW
Po=120mW
CW
Po
λp
Ith
-
410
-
-
-
120
420
50
4
Φ
2.0±0.2
Y+
34
110
1.6
4.7
-
( ) are reference figures
Po=120mW
CW
Iop
-
150
2.0
Pin Connection
1.2
-
η
Vop
θ//
θ⊥
∆θ//
∆θ⊥
Im
Po=120mW
6.0
Parallel
Beam
7.0
13.0
-2.0
-2.5
-
12.0
28.0
2.0
°
°
°
Po=120mW
Divergence*
Perpendicular
Parallel
-
-
Beam Pointing
Accuracy
Po=120mW
Po=120mW
Perpendicular
-
2.5
°
This model has a Zener Diode built in
as a protection circuit against static
electricity.
Monitor Current**
-
1.0
mA
* Full angle at 50% from peak intensity
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
ꢁ
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
ꢁ
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
ꢂHEAD OFFICE
NICHIA CORPORATION
http://www.nichia.co.jp
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
ꢂCONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-