YTB-SC0018-01
]
2012/10/12
Violet Laser Diode for External Cavity
Test Sample
NDVA111T
ꢀ
Features
• For External Cavity Laser with Low Reflection Coating on front facet
• Optical Output Power: 45mW
Outline Dimension
Unit (mm)
• Can Type:
φ 5.6 mm Cathode Ground
°
ꢀ
Absolute Maximum Ratings
Absolute Maximum
Ratings
Item
Symbol
Unit
Optical Output Power
LD Forward Current
Po
If
65
120
mW
mA
V
LD Reverse Voltage
Vr (LD)
Tstg
Tc
2
Storage Temperature
-25 ~ 75
10 ~ 55
°C
Operating Case Temperature
°C
ꢀ
Initial Electrical/Optical Characteristics
Item
(Ta=23°C *1)
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
CW
Po
-
-
45
mW
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Po=45mW
CW
400
-
50
72
1.8
4.3
-
410
-
nm
mA
mA
W/A
V
λp
Ith
-
-
Po=45mW
CW
Iop
η
-
( ) are reference figures
-
-
Pin Connection
1
2
Po=45mW
Vop
θ//
-
-
7
12
23
2.0
2.5
deg.
deg.
deg.
deg.
Beam Divergence*2
Emission
Po=45mW
Po=45mW
LD
15
-2.0
-2.5
-
θ⊥
1. LD Anode
2. NC
-
∆θ//
∆θ⊥
Angle
Point
Accuracy
3. LD Cathode
3
-
This model does not have Photo Diode.
*1 There is some range in ambient temperature.
*2 Full angle at 50% from peak intensity
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
Diffractive feedback efficiency to the Laser diode must be limited less than 20 % under the External cavity configuration.
This model is Test Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
ꢁ
ꢁ
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
ꢂHEADQUARTERS
NICHIA CORPORATION
http://www.nichia.co.jp
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
ꢂCONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-