MDHU100 Series
4000VAC I/O Isolation
Single and Dual Outputs
Rev B
2 Watt Medical DC/DC Converter
FEATURES
● Low Cost
● Single and Dual Outputs
● MTBF > 2,000,000 Hours
● Internal SMT Construction
● Operating Temperature: -25°C to +60°C
● Medical & Industrial Safety: UL60601-1 and UL60950-1
● RoHS Compliant
● Efficiency up to 75%
● Low Leakage Current
● 4000VAC I/O Isolation
DESCRIPTION
The MDHU100 series power modules are 2W DC/DC converters that are specially designed to provide ultra-high levels of isolation
(4000VAC) in a miniature DIP package. These converters operate over input voltage ranges of 4.5~5.5VDC, 10.8~13.2VDC, and
21.6~26.4VDC. This series also has single and dual output voltages of 5, 12, 15, ±12, and ±15VDC. These converters have both medical
(UL60601-1) and industrial (UL60950-1) safety approvals and are useful for a variety of applications including distributed power systems,
mixed analog/digital subsystems, portable test equipment, local power networks, and battery-backed systems.
SPECIFICATIONS: MDHU100Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (Vin)
TEST CONDITIONS
Min
Nom
Max
Unit
5V nominal input models
12V nominal input models
24V nominal input models
All models
5V nominal input models
12V nominal input models
24V nominal input models
All models
4.5
10.8
21.6
5
12
24
5.5
13.2
26.4
0.3
9
Input Voltage Range
VDC
A
Reverse Polarity Input Current
Input Surge Voltage (1000ms)
-0.7
-0.7
-0.7
18
30
VDC
Input Filter
Leakage Current
Internal Capacitor
2
240VAC, 60Hz
μA
OUTPUT (Vo)
Output Voltage
See Rating Chart
Output Voltage Accuracy
Output Voltage Balance
Load Regulation
±2.0
±0.1
See Rating Chart
±4.0
±1.0
%
%
Dual Output, Balanced Loads
Io = 20% to 100%
Line Regulation
Output Power
Vin = min. to max.
±1.2
±1.5
2
%
W
Output Current Range
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
PROTECTION
See Rating Chart
100
150
200
15
mVpk-pk
mVpk-pk
mVrms
Over Line, Over Load, and Over Temperature
Short Circuit Protection
0.5 seconds max.
1000mA slow-blow type
500mA slow-blow type
200mA slow-blow type
5V nominal input models
12V nominal input models
24V nominal input models
Input Fuse Recommendation
GENERAL
Efficiency
See Rating Chart
Switching Frequency
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Internal Power Dissipation
Max. Capacitive Load
ENVIRONMENTAL
Operating Temperature (Ambient)
Operating Temperature (Case)
Storage Temperature
Lead Temperature
Humidity
50
4000
6000
10
80
100
KHz
VAC
VDC
GΩ
pF
mW
60 seconds
Flash Test for 1 second
500VDC
100KHz, 1V
15
20
650
See Rating Chart
Ambient
Case
-25
-25
-40
+60
+90
+125
260
95
°C
°C
°C
°C
%
1.5mm from case for 10 seconds
Cooling
Free air convection
Temperature Coefficient
MTBF
±0.01
±0.02
%/°C
Khours
MIL-HDBK-217F @ 25°C, Ground Benign
2000
PHYSICAL
Weight
0.18oz (5.1g)
0.94 x 0.54 x 0.34 inches
23.8 x 13.7 x 8.62 mm
Dimensions (L x W x H)
Case Material
Flammability
Non-conductive black plastic
UL94V-0
SAFETY
Industrial Approvals
Medical Approvals
UL60950-1
UL60601-1
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833