Power Module
Package S Rectifier Diode Module
Absolute Maximum Ratings (TC = 25°C, unless otherwise specified)
Values
Symbol
Parameters
Test Conditions
Unit
IF(AV)
Average Forward Current
RMS Forward Current
130
204
160
180
280
200
310
A
A
Single phase, half wave
180°C conduction, Tc1
IF(RMS)
250
5500
6000
151.2
149.4
694
Tc=45°C, 50Hz, Single wave
Tc=45°C, 60Hz, Single wave
Tc=45°C, 50Hz, Single wave
Tc=45°C, 60Hz, Single wave
3500
3800
61.2
60.0
625
6000
6500
180.0
175.3
694
6500
7000
211.2
203.3
781
Non-Repetitive Surge Forward
Current
IFSM
A
I2t
I2t (For Fusing)
KA2s
PD
Power Dissipation
JunctionTemperature
W
°C
°C
TJ
-40 to +150
-40 to + 125
TSTG
StorageTemperature Range
Visol
InsulationTest Voltage
AC, 50Hz, t=1min
3000
V
Note: 1. for MDxx130S & MDxx160S, TC=95°C; for MDxx180S, TC=90°C; for MDxx200S, TC=85°C
Electrical andThermal Specifications (TC = 25°C, unless otherwise specified)
Symbol
Parameters
Test Conditions
Min
Typ
Max
500
10
Unit
μA
VR=VRRM
VR=VRRM , TJ=125°C
IF=400A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
IRM
Reverse Leakage Current
mA
1. 5
MDxx130S
MDxx160S
MDxx180S
MDxx200S
MDxx130S
MDxx160S
MDxx180S
MDxx200S
IF=500A
1. 5
VF
VT0
rT
Forward Voltage
V
V
IF=600A
1. 5
IF=600A
1. 5
0.85
0.85
0.82
0.80
1. 6
For power-loss calculations only
TJ=125°C
MDxx130S
MDxx160S
MDxx180S
MDxx200S
1.2
mΩ
1. 1
1. 0
Mechanical Characteristics
Symbol
Torque
Torque
Parameters
Module-to-Sink
Module Electrodes
Test Conditions
Min
3
Typ
Max
Unit
N·m
N·m
Recommended (M6)
Recommended (M6)
5
5
3
Electrical andThermal Specifications (TC = 25°C, unless otherwise specified)
Symbol
Parameters
Max
Unit
0.20
0.18
0.18
0.16
MDxx130S
MDxx160S
MDxx180S
MDxx200S
RthJC
Junction-to-Case
K/W
Rectifier Module Circuit Series- Package S
©2014 Littelfuse, Inc
Specifications are subject to change without notice.
Revised:02/19/14
2