Specification for an Highpass LC Filter
MtronPTI P/N: LF9412
I. General & Electrical Requirements
1. Corner Frequency (FON): 1215MHz
2. Passband: 1215MHz to 1400MHz
3. Passband Insertion Loss: ≤ 0.7dB
4. Passband VSWR: ≤ 1.4:1
5. Passband Phase Linearity: ≤ 9
6. Rejection (Minimum, Relative to Insertion Loss)
35dB: 960MHz to 1100MHz
7. Signal Level: ≤ -16dBm CW, ≤ +51dBm 2msec pulsed 40% duty cycle
8. ZS/ZL: 50Ω nominal
Note: The filter shall meet all performance requirements over the full operating temperature range (-40C to +85C)
II. Environmental & Physical Requirements:
1. Temperature Range
Operating: -40C to +85C
Non-Operating: -55C to +125C
2. Altitude:
Operating: Sea Level to 10,000-ft
Non-Operating: Sea Level to 40,000-ft
3. Humidity: 0 to 100% Relative Humidity
4. Salt Atmosphere: Per MIL-STD-810F, Method 521.2
5. Vibration: Per MIL-STD-810F, Method 514.5,
Category 4, 6, 11, 17, 18 & 21, Procedure I, II & IV
6. Shock: Per MIL-STD-810F, Method 516.5,
Procedure I (Functional) & VII (Rail)
7. Temperature Cycling: Per MIL-STD-883, Method 1010.8, Test Condition B
8. Materials and Finish: Non-nutrient to fungus and non-corrosive in the specified application environment
9. Package (see Figure 1):
Figure 1 –Filter Package Outline Drawing
Rev. - 09/06/12
Page 1 of 2
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without the express written permission of MtronPTI