5秒后页面跳转
KSE-61-L3 PDF预览

KSE-61-L3

更新时间: 2024-09-27 02:49:55
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
5页 160K
描述
Plug-in Signal Conditioners K-UNIT

KSE-61-L3 数据手册

 浏览型号KSE-61-L3的Datasheet PDF文件第2页浏览型号KSE-61-L3的Datasheet PDF文件第3页浏览型号KSE-61-L3的Datasheet PDF文件第4页浏览型号KSE-61-L3的Datasheet PDF文件第5页 
MODEL: KSE  
Plug-in Signal Conditioners K-UNIT  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
DC ALARM  
(dial adjustment)  
Functions & Features  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
• Providing SPDT relay outputs at preset DC input levels  
• Single or Dual (Hi/Lo) trip  
• Large dial setpoint adjustments  
/C02: Polyurethane coating  
/C03: Rubber coating  
Typical Applications  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
• Various alarm applications  
50  
(1.97)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
K-UNIT  
80  
(3.15)  
100  
SET1  
Screw terminal: Chromated steel (standard) or stainless  
steel  
ModelKSE  
50  
%
0
100  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
50  
%
145  
(5.71)  
*
SET2  
0
Setpoint adjustments: Dials (front), -15 – +120 %  
independently; Scales at the front are for approximate  
aim only. Simulate input signals, confirm relay operation  
and set.  
mm (inch)  
*
136 (5.35) for KSE–x1  
MODEL: KSE–[1][2]–[3][4]  
Hysteresis (deadband): Approx. 1 %  
Front LEDs: Red LED turns on when the coil is energized.  
ORDERING INFORMATION  
• Code number: KSE-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. KSE-A2-K3/Q)  
INPUT SPECIFICATIONS  
DC Current:  
Shunt resistor attached to the input terminals (0.5 W)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
OUTPUT SPECIFICATIONS  
Relay Contact: 120 V AC @1 A (cos ø = 1)  
(Limited within 0.5 A to conform with EU Directive)  
240 V AC @0.5 A (cos ø = 1)  
[1] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
Voltage  
(Limited within 0.5 A to conform with EU Directive)  
30 V DC @1 A (resistive load)  
6: 1 – 5 V DC (Input resistance 500 kΩ min.)  
(Limited within 0.5 A to conform with EU Directive)  
Maximum switching voltage: 380 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @10 mA  
[2] OUTPUT  
1: Single trip (Hi)  
2: Dual trip (Hi/Lo)  
Mechanical life: 5 × 10 cycles  
7
[3] POWER INPUT  
AC Power  
K3: 100 – 120 V AC  
(Operational voltage range 90 – 132 V, 47 – 66 Hz)  
L3: 200 – 240 V AC  
(Operational voltage range 180 – 264 V, 47 – 66 Hz)  
KSE SPECIFICATIONS  
ES-3609 Rev.9 Page 1/5  
https://www.m-system.co.jp/  

与KSE-61-L3相关器件

型号 品牌 获取价格 描述 数据表
KSE-61-L3/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KSE-62-K3 MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KSE-62-K3/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KSE-62-L3 MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KSE-62-L3/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KSE700 FAIRCHILD

获取价格

Monolithic Construction With Built-in Base- Emitter Resistors
KSE700S FAIRCHILD

获取价格

Power Bipolar Transistor, 4A I(C), 60V V(BR)CEO, 1-Element, PNP, Silicon, TO-126, Plastic/
KSE700STU ROCHESTER

获取价格

4A, 60V, PNP, Si, POWER TRANSISTOR, TO-126
KSE700STU FAIRCHILD

获取价格

Power Bipolar Transistor, 4A I(C), 60V V(BR)CEO, 1-Element, PNP, Silicon, TO-126, Plastic/
KSE701 FAIRCHILD

获取价格

Monolithic Construction With Built-in Base- Emitter Resistors