VDE
COMPACT POWER RELAYS
FEATURES
JC-RELAYS
30.0
1.181
19.0
.748
• High inrush current capability
1 Form A: 163 A inrush (TV-8)
2 Form A: 111 A inrush (TV-5)
• High dielectric withstanding for transient protection:
JC can withstand 10,000 V surge in µs between coil and contact.
30.4
1.197
• Electrical life:
1 Form A: 105 ope. at 15 A 250 V AC resistive load
2 Form A: 105 ope.
at 10 A 250 V AC resistive load
mm inch
• TÜV also approved
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
2 Form A
Maximum operating speed
Initial insulation resistance*1
20 cpm.
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 mΩ
(Cd free type: 100 mΩ)
Silver alloy
Min. 100 MΩ at 500 V DC
2,000 V rms for 1 min.
(N.C. contact of 1a1b: 1,000 Vrms)
Between open contacts
Initial
Contact material
breakdown
voltage*2
Contact force, min.
Maximum switching power
30 g
Between contacts sets
Between contacts and coil
2,000 Vrms for 1 min.
4,000 Vrms for 1 min.
3,750 VA
250 V AC
15 A
2,500 VA
250 V AC
10 A
Rating
(resistive
load)
Maximum switching volt-
age
Operate time*3
(at nominal voltage)
Release time(without diode)*3
(at nominal voltage)
Approx. 15 ms
Approx. 2 ms
Max. 55°C
Max. switching current
Mechanical
Expected
5×106
Temperature rise
(at nominal voltage)
life (min.
operation)
10 A 250 V AC
5A 250 V AC
105
—
—
105
Electrical
(resistive)
Functional*4
196 m/s2 {20 G}
980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
[1a1b type at double amplitude:
1.0 mm, 58.8 m/s2 {6 G}]
Shock
Coil
Destructive*5
Functional*6
resistance
Minimum operating power
Nominal operating power
Remarks
576 mW
900 mW
640 mW
1,000 mW
Vibration
resistance
* Specifications will vary with foreign standards certification ratings.
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
*1 Measurement of same location as "Intial breakdown voltage" section
*2 Detection current: 10mA
Destructive
*3 Excluding contact bounce time
Conditions for operation,
transport and storage*7
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
–50°C to +60°C –58°F to +140°F
*6 Detection time: 10µs
Humidity
5 to 85%R.H.
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Unit weight
Approx. 31 g 1.09 oz
TYPICAL APPLICATIONS ORDERING INFORMATION
Automatic garage door openers
Microwave ovens
Dryers
Ex. JC
1a
F
TM
DC12V
Vending machines
Copiers
Contact
arrangement
Mounting classification
Coil voltage
Air conditioners
Stereo equipment
TV sets
Nil: PC board terminal
S: Plug-in terminal
TM: Top mounting
1a: 1 Form A
2a: 2 Form A
DC 5, 6, 12, 24, 48 V
(Notes) 1. TV rated types available 1 Form A: TV 8; 2 Form A: TV-5.
Notes ))2. For UL/CSA recognized types, add suffix UL/CSA.
Notes ))3. Standard packing Carton: 50 pcs.; Case: 200 pcs.
Notes ))4. For Cd free contact material type, add suffix “-F”.
105