HITRON 开关医疗输出元件输入元件
页数 文件大小 规格书
2页 139K
描述
UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME SINGLE OUTPUT 63 WATTS INTERNAL SWITCHING POWER SUPPLIES

HMI63-S150400 数据手册

 浏览型号HMI63-S150400的Datasheet PDF文件第2页 
H HiTRON  
UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME  
SINGLE OUTPUT 63 WATTS INTERNAL SWITCHING  
POWER SUPPLIES HMI63 SERIES  
FEATURES:  
„ ACCOMMODATE UNIVERSALAC SOURCES  
„ COMPACT 4”x2”x1”PCB FORMAT  
„ MEET MEDICAL STANDARD EN 60601-1/  
UL 2601-1  
„ EMI MEET EN 55011 & FCC CLASS B  
„ CE MARKING COMPLIANCE  
SPECIFICATION  
OUTPUT SPECIFICATION  
Output Voltage: See Ratings Chart.  
Output Current: See Ratings Chart.  
Output Connector: V-M connector.  
Output Wattage: Typ. 62 watts.  
INPUT SPECIFICATION  
Input Voltage: Range typ. 90-264Vac.  
Rating 100 to 240Vac.  
Input Connector: V-M connector.  
Line Regulation: Typ. 0.1%.  
Load Regulation: Typ. ±1.0%.  
Noise & Ripple: Typ. 1.0% peak to peak.  
OVP: Built-in at main output (Latch).  
Adjustability: Factory Set.  
Input Frequency: 47-63Hz.  
Inrush Current: 12.0A rms cold start @230Vac.  
Input Current: Typ. 0.9A@115Vac, 0.435 @230Vac.  
Dielectric Withstand: Meet IEC 60601-1.  
EMI: Meet EN 55011 & FCC Class B.  
Hold-up Time: Typ. 11.2mS @115Vac, 72mS @ 230Vac.  
Earth Leakage: Less than 0.1mA @230Vac.  
Overload Protection (OLP):  
Fully protected against outputs overload and short circuit.  
Typ. OLP set at 105-120% of rating output power.  
Consult the factory for OLP setting.  
GENERAL SPECIFICATION  
Efficiency: Typ. 80-89.5 %. (Various with output voltage).  
Operating Temperature: 0 to +50 °C under forced air flow  
for full load. Derate by 1.3W/°C  
Switching Frequency: 85KHz.  
Circuit Topology: Fixed frequency flyback circuit.  
Transient Response: Output voltage returns in less than  
from 40°C to 50°C.  
Storage Temperature: -20 to +85°C.  
0.5mS following a 50% load change. Temperature Coefficient: Typ. 0.04%/°C.  
Safety Standard: Meet Medical standards UL 2601-1/  
EN 60601-1 Class I.  
Cooling: At least 5 cfm direct forward air flow is required to  
achieve full rating power.  
Power Density: 7.7Watts / Cubic Inch.  
Construction: 4”x2”x1” PCB format.  
Note: Due to requests in market and advances in technology, specifications subject to change without notification.  
For the details of safety approval, please consult the factory.  
-15-  

与HMI63-S150400相关器件

型号 品牌 获取价格 描述 数据表
HMI63-S240250 HITRON

获取价格

UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME SINGLE OUTPUT 63 WATTS INTERNAL SWITC
HMI63-S480125 HITRON

获取价格

UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME SINGLE OUTPUT 63 WATTS INTERNAL SWITC
HMIB001BU1H3 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU1H5 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU5H3 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU5H5 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU6H3 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU6H5 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU7H3 SENSORTECHNICS

获取价格

HMIM100U
HMIB001BU7H5 SENSORTECHNICS

获取价格

HMIM100U