Digital Pressure Sensor DP-0SERIES
706
ORDER GUIDE
FIBER
SENSORS
LASER
Model No.
SENSORS
DP-00 1 - P - J
PHOTO-
ELECTRIC
SENSORS
MICRO
Rated pressure range
Cable
None : Connector attached cable 2 m 6.562 ft
: Type without connector attached cable
PHOTO-
ELECTRIC
SENSORS
1 : −100.0 to +100.0 kPa (Low pressure type)
2 : 0.000 to +1.000 MPa (High pressure type)
AREA
J
SENSORS
SAFETY LIGHT
CURTAINS
SAFETY
/
Comparative output
COMPONENTS
None : NPN output type
PRESSURE /
FLOW
SENSORS
P
: PNP output type
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
Type
Appearance
Rated pressure range
Model No.
Pressure port
Comparative output
SENSORS
SENSOR
OPTIONS
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
DP-001
Low pressure
type
−100.0 to +100.0 kPa
0.000 to +1.000 MPa
SIMPLE
DP-001-P
DP-002
WIRE-SAVING
UNITS
M5 female thread
*CN-14A-C2
(Connector attached cable
2 m 6.562 ft ) is attached.
High pressure
type
WIRE-SAVING
SYSTEMS
DP-002-P
MEASURE-
MENT
SENSORS
Type without connector attached cable
Accessory
STATIC
CONTROL
DEVICES
Type without connector attached cable CN-14A-C2 is available. When ordering
this type, suffix “-J” to the Model No.
• CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
•
(e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J”
LASER
MARKERS
PLC
HUMAN
OPTIONS
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Recommended connector
Designation
Model No.
CN-14A-C1
Description
Contact: SPHD-001T-P0.5,
Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
FA
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
COMPONENTS
CN-14A-C2 (Note)
CN-14A-C3
Connector
attached cable
MACHINE
VISION
SYSTEMS
CN-14A-C5
Recommended crimping tool
UV
CURING
SYSTEMS
0.2 mm2 4-core bending-resistant
cabtyre cable with connector on
one end
Cable outer diameter: ø3.7 mm
ø0.146 in
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-14A
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Connector
attached cable
Bending-resistant
(
)
cable
Recommended connector (e-CON)
Selection
Guide
Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Connector
Set of 10 housings and 40 contacts
Pressure/
Allows sensors to be installed on the flooring or ceiling.
Digital Display
MS-DP1-1
MS-DP1-5
MS-DP1-8
MS-DP1-3
MS-DP1-7
Multiple sensors can also be mounted closely.
Sensor mounting
bracket
Pressure/
Note: Contact the manufacturer for details
of the recommended products.
Head-separated
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Flow
Panel mounting
bracket
Allows installation to panels with thickness of 1 to 3 mm 0.039
to 0.118 in. Multiple sensors can also be mounted closely.
DP-0
Front protection
cover
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
DP-100
DP-M
Conversion
bushing
Pressure port can be converted to Rc1/8 female thread.
Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series.