D2002UK
ELECTRICAL CHARACTERISTICS (T
= 25°C unless otherwise stated)
case
Parameter
Test Conditions
Min.
Typ.
Max. Unit
Drain–Source
BV
V
= 0
I = 10mA
65
V
DSS
GS
D
Breakdown Voltage
Zero Gate Voltage
I
V
V
= 28V
= 20V
V
= 0
2
mA
DSS
DS
GS
Drain Current
I
Gate Leakage Current
Gate Threshold Voltage*
Forward Transconductance*
Common Source Power Gain
Drain Efficiency
V
V
= 0
= V
1
7
μA
V
GSS
GS
DS
DS
V
g
I = 10mA
1
GS(th)
D
GS
V
P
V
= 10V
I = 0.4A
0.36
13
S
fs
DS
D
G
= 5W
dB
%
PS
O
η
= 28V
I
= 0.2A
DQ
40
DS
VSWR Load Mismatch Tolerance
f = 1GHz
= 0
20:1
—
pF
pF
pF
C
C
C
Input Capacitance
V
V
V
V
V
V
= –5V f = 1MHz
24
12
1
iss
DS
GS
GS
GS
Output Capacitance
= 28V
= 28V
= 0
= 0
f = 1MHz
f = 1MHz
oss
rss
DS
DS
Reverse Transfer Capacitance
* Pulse Test:
Pulse Duration = 300 μs , Duty Cycle ≤ 2%
HAZARDOUS MATERIAL WARNING
The ceramic portion of the device between leads and metal flange is beryllium oxide. Beryllium oxide dust is highly
toxic and care must be taken during handling and mounting to avoid damage to this area.
THESE DEVICES MUST NEVER BE THROWN AWAY WITH GENERAL INDUSTRIAL OR DOMESTIC WASTE.
THERMAL DATA
R
Thermal Resistance Junction – Case
Max. 6.0°C / W
THj–case
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
Document Number 3500
Issue 2
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk