BLP30 AC-DC Series Data Sheet
30 Watts
Features
•
•
RoHS compliant for all six substances
2” x 4” footprint
•
•
•
•
•
•
•
•
•
•
Component height less than 1”
25 W rating with natural convection cooling
30 W rating with 10 CFM airflow
Compliance to EMI Class B
Universal AC input
Short-circuit protection
Overvoltage protection
Applications
CE marked to Low Voltage Directive (Pending)
Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
Two-year warranty
•
•
•
•
•
•
•
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
Total
Ripple &
Noise
Regulation
(Amps) 2
pk-pk % 4
(VDC)
(%) 3
± 2
BLP30-1005G
BLP30-1012G
BLP30-1024G
5V
0 – 5
0 – 6
0 – 2.5
0 – 1.25
7.2
3.0
1.5
1
1
12V
24V
0 – 2.1
0 – 1.0
± 2
0.6
± 2
Triple-Output Model Selection
Model
Nominal
Output Voltage
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
Total
Ripple &
Noise
Regulation
(Amps) 2
pk-pk % 4
(VDC)
+5V
(%) 3
±2
0.2 – 2.5
0.1 – 1.2
0.0 – 0.3
0.2 – 3.5
0.1 – 2.0
0.0 – 0.5
5
3
1
1%
1%
1%
BLP30-3000G
+12V
-12V
±5
±5
1
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line, and load regulation
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
2
3
4
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com