Click on Series name for product info on aimtec.com
Series AME30-MAZ
30 Watt | AC-DC / DC-DC Converter
FEATURES:
4000VAC I/O isolation
Medical Switching power modules for PCB mounting
Operating temperature: -40 to +85°C
Energy star compliant
RoHS compliant
Low Ripple and Noise
CE, cULus, BC approvals
Universal Input: 90-264VAC, 47-440Hz, or 130-370VDC
Models
Single output
CB
Efficiency
Output
Voltage
(V)
Maximum
Capacitive
load (µF)
Output Current
(%)
Input Voltage
(VAC/Hz)
Input Voltage
Model
max
(A)
(VDC)
115
230
VAC
VAC
AME30-3.3SMAZ
AME30-5SMAZ
AME30-12SMAZ
AME30-15SMAZ
AME30-24SMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
130-370
130-370
3.3
5
12
15
24
8200
8200
2200
1500
560
6
6
2.5
2
79
82
84
84
83
77
81
82
82
82
1.25
Models
Dual output
Efficiency
(%)
Output
Voltage
(V)
Maximum
Capacitive
load (µF)
Output Current
Input Voltage
Input Voltage
(VDC)
Model
max
(A)
(VAC/Hz)
115
230
VAC
VAC
AME30-5DMAZ
AME30-12DMAZ
AME30-15DMAZ
AME30-24DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-260/47-440
130-370
130-370
130-370
130-370
±5
±12
±15
±24
3300
2200
1000
470
±3
±1.25
±1
80
82
82
77
80
82
81
76
±0.625
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
Units
mA
mA
A
740
410
25
Current
Inrush current <2ms
A
50
Leakage current
External fuse
Input dissipation
Start-up time
µA
A
W
150
Recommended slow blow type
115 / 230 VAC
3.15
0.5
250
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Conditions
Typical
±2
Maximum
Units
%
%
(LL-HL)
0-100% load single
0-100% load dual
±1
±1
±2
±5
Load regulation
%
Cross regulation
Transient response deviation
25% load - 1st out, 100% load – 2nd out
25% load Step
%
±2
% of Vout
3.3 / 5V models
75
Ripple & Noise*
12 / 15V models
24V models
100
150
25
mV p-p
Hold-up time (min)
ms
Minimum Load Current
0
% of Max
*Ripple & Noise measured at 20MHz bandwidth by using with 0.1μF M/C and47μF E/C
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)