Click on Series name for product info on aimtec.com
Series AME3-AZ
3Watt | AC-DC Converter
FEATURES:
• I/O Isolation 3000VAC
• RoHS compliant
• Energy Star compliant
• Ultra small package
• Operating Temp: -40oCto +80oC
• Over load, Short Circuit Protection
• Input: 90-305VAC, 47-440Hz, or 130-430 VDC
• Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Models
Single output
Maximum
capacitive
Load
Efficiency
Full load (%)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current max
(mA)
Model
115
230
277
480
(ºC)
VAC
VAC
VAC
VAC
(µF)
2200
1100
680
560
470
AME3-3.3SAZ
AME3-5SAZ
AME3-12SAZ
AME3-15SAZ
AME3-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
900
600
250
200
125
63
67
75
78
81
64
67
73
74
81
62
65
70
71
80
AME3-3.3SBAZ
AME3-5SBAZ
AME3-12SBAZ
AME3-15SBAZ
AME3-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
700
600
250
200
125
2200
1100
680
560
470
61
67
72
72
71
61
67
72
71
71
60
66
70
70
69
54
60
61
61
62
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
480VAC
Typical
Maximum
Units
mA
mA
mA
mA
A
A
A
A
80
40
35
30
10
15
20
30
Current (full load)
115 VAC
230 VAC
277 VAC
480 VAC
Inrush current <2ms (cold start)
Leakage current
External fuse
0.15
mA
A
Recommended slow blow type
1
Input Dissipation (No Load)
W
≦0.3
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Conditions
Full load (typical)*
LL-HL, Full Load
Typical
±5
Maximum
Units
%
%
%
µs
±3
±5
200
±2
0
0-100% load (typical)*
25% load step
% of Vout
%
3.3/5 VDC With 560µF E/C
12/15 VDC With 220µF E/C
24 VDC With 220µF E/C
200
400
500
mV p-p
mV p-p
mV p-p
Ripple & Noise
*Ripple & Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480VAC (Typical input ) with Full Load
Isolation Specifications
Parameters
Conditions
Typical
Rated
3000
Units
VAC
MΩ
Tested I/O voltage
60 sec
Isolation Resistance
>1000
www.aimtec.com
F 052e R8.J
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only