5秒后页面跳转
AFE4950 PDF预览

AFE4950

更新时间: 2024-09-19 02:52:11
品牌 Logo 应用领域
德州仪器 - TI 监控
页数 文件大小 规格书
8页 977K
描述
AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and Electrical Bio-sensing

AFE4950 数据手册

 浏览型号AFE4950的Datasheet PDF文件第2页浏览型号AFE4950的Datasheet PDF文件第3页浏览型号AFE4950的Datasheet PDF文件第4页浏览型号AFE4950的Datasheet PDF文件第5页浏览型号AFE4950的Datasheet PDF文件第6页浏览型号AFE4950的Datasheet PDF文件第7页 
AFE4950
SBASA37A – JUNE 2020 – REVISED OCTOBER 2020  
AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring,  
SpO2 and Electrical Bio-sensing  
Acquire data synchronized with system master  
clock  
1 Features  
Supports simultaneous & synchronized acquisition  
of up to 24 PPG and a single-lead ECG signal.  
Flexible allocation of 8 LED, 4 PD in each phase  
ECG signal chain:  
– 1-lead ECG signal acquisition up to 2 kHz  
– RLD output to drive a third electrode  
– Input noise : 0.7 µV-rms  
– Supports up to +/- 0.65 V differential DC offset  
and +/-0.55 V common mode range  
– Programmable INA gain: 11, 21  
– High-pass filter with quick saturation recovery  
– Integrated 300 Hz anti-aliasing low pass filter  
– AC, DC lead-off detect: 2.6-nA to 85-nA  
– Low power continuous lead-on detection  
Impedance signal chain  
– Continuous low-power monitoring of impedance  
between 2 electrodes  
– 7 MΩ range  
– 300 Ω noise on 620 kΩ  
PPG Transmitter:  
– 8-Bit Programmable LED Current with range  
adjustable from 25 mA to 250 mA  
– Mode to fire two LEDs in parallel  
– Support of 8 LEDs in Common Anode  
configuration for SpO2, Multi-Wavelength HRM  
PPG Receiver:  
– 2 parallel receivers (two sets of TIA/ filter)  
– Supports 4 Time-Multiplexed Photodiode Inputs  
to each Receiver  
FIFO with 256-sample Depth  
SPI, I2C interfaces: Selectable by pin  
2.6-mm × 2.5-mm DSBGA, 0.4-mm Pitch  
Supplies: Rx:1.7-1.9V (LDO Bypass); 1.9-3.6V  
(LDO Enabled), Tx:3-5.5V, IO:1.7-RX_SUP  
2 Applications  
Optical Heart-Rate Monitoring (HRM) for  
Wearables, Hearables  
High performance ECG signal acquisition  
Synchronized PPG, ECG for BP estimation  
Heart-rate variability (HRV)  
Pulse oximetry (SpO2) measurements  
3 Description  
The AFE4950 device is an analog front-end (AFE) for  
synchronized signal acquisition of PPG and ECG  
signals. The device can also be used for optical bio-  
sensing applications, such as heart-rate monitoring  
(HRM) and saturation of peripheral capillary oxygen  
(SpO2). The ECG signal chain supports 2- and 3-  
electrode configurations and has an integrated Right  
leg drive (RLD) buffer. The ECG signal chain can also  
be used to do a continuous, low-power monitoring of  
the impedance between pair of electrodes.  
Device Information  
PART NUMBER  
AFE4950  
PACKAGE(1)  
BODY SIZE (NOM)  
DSBGA (36)  
2.60 mm × 2.50 mm  
(1) For all available packages, see the orderable addendum at  
the end of the data sheet.  
– 8-bit Ambient Offset subtraction at each TIA  
input with 256 µA range  
– 8-bit LED Offset Subtraction DAC with 64 µA  
range  
– Automatic ambient cancellation and dynamic  
LED DC cancellation at TIA input  
– Ambient rejection close to 100 dB up to 10 Hz  
– Noise filtering with programmable bandwidth  
– Trans-impedance Gain: 3.7 kΩ to 1 MΩ  
Accurate, Continuous Heart-Rate Monitoring:  
– System SNR up to 109-dB at 16 µA PD current  
– Low Current for Continuous Operation on a  
Wearable Device with a Typical Value: 15-μA  
for an LED, 20-μA for the Receiver  
External clock and internal oscillator modes  
Simplified Schematic  
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,  
intellectual property matters and other important disclaimers. PRODUCTION DATA.  
 
 

与AFE4950相关器件

型号 品牌 获取价格 描述 数据表
AFE4950_V01 TI

获取价格

AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and E
AFE4950_V02 TI

获取价格

AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and E
AFE4950YBGR TI

获取价格

AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and E
AFE4950YBGT TI

获取价格

AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and E
AFE4960 TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 模拟前端
AFE4960P TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 和 PPG 模拟前端
AFE4960PYBGR TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 和 PPG 模拟前端 | YBG | 3
AFE4960PYBGT TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 和 PPG 模拟前端 | YBG | 3
AFE4960YBGR TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 模拟前端 | YBG | 36 | -4
AFE4960YBGT TI

获取价格

具有集成式呼吸和起搏信号检测功能的双通道 ECG 模拟前端 | YBG | 36 | -4