AD5516
ABSOLUTE MAXIMUM RATINGS1, 2
(TA = 25°C, unless otherwise noted.)
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Junction Temperature (TJ MAX) . . . . . . . . . . . . . . . . . . . 150°C
74-Lead CSPBGA Package, JA Thermal Impedance . . . 41°C/W
Reflow Soldering
VDD to AGND . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +17 V
VSS to AGND . . . . . . . . . . . . . . . . . . . . . . . . .+0.3 V to –17 V
AVCC to AGND, DACGND . . . . . . . . . . . . . . .–0.3 V to +7 V
DVCC to DGND . . . . . . . . . . . . . . . . . . . . . . . .–0.3 V to +7 V
Digital Inputs to DGND . . . . . . . . . . . –0.3 V to DVCC + 0.3 V
Digital Outputs to DGND . . . . . . . . . . –0.3 V to DVCC + 0.3 V
REF_IN to AGND, DACGND . . . . . . –0.3 V to AVCC + 0.3 V
VOUT0–15 to AGND . . . . . . . . . . . . VSS – 0.3 V to VDD + 0.3 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
RFB0–15 to AGND . . . . . . . . . . . . . VSS – 0.3 V to VDD + 0.3 V
Operating Temperature Range, Industrial . . . . . –40°C to +85°C
Peak Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . 220°C
Time at Peak Temperature . . . . . . . . . . . . . 10 sec to 40 sec
NOTES
1Stresses above those listed under Absolute Maximum Ratings may cause permanent
damage to the device. This is a stress rating only; functional operation of the device
at these or any other conditions above those listed in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
2Transient currents of up to 100 mA will not cause SCR latch-up.
ORDERING GUIDE
Output Voltage Span
Model
Function
Package Option
AD5516ABC-1
AD5516ABC-2
AD5516ABC-3
EVAL-AD5516-1EB
EVAL-AD5516-2EB
EVAL-AD5516-3EB
16 DACs
16 DACs
16 DACs
2.5 V
5 V
10 V
74-Lead CSPBGA
74-Lead CSPBGA
74-Lead CSPBGA
Evaluation Board
Evaluation Board
Evaluation Board
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD5516 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
REV. B
–5–