9ZXL0832E / 9ZXL0852E Datasheet
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the 9ZXL0832E / 9ZXL0852E. These ratings, which are standard
values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these or any other conditions above
those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods can affect product reliability. Electrical parameters are guaranteed only over the recommended operating temperature range.
Parameter
Supply Voltage
Input Low Voltage
Symbol
VDDx
VIL
Conditions
Minimum
Typical Maximum Units Notes
3.9
V
V
1,2
1
GND-0.5
Input High Voltage
Input High Voltage
VIH
Except for SMBus interface
SMBus clock and data pins
VDD+0.5
V
V
1,3
1
VIHSMB
3.9
150
125
Storage Temperature
Junction Temperature
Input ESD Protection
Ts
Tj
ESD prot
-65
°C
°C
V
1
1
1
Human Body Model
2500
1 Guaranteed by design and characterization, not 100% tested in production.
2 Operation under these conditions is neither implied nor guaranteed.
3 Not to exceed 3.9V.
Electrical Characteristics–DIF_IN Clock Input Parameters
TAMB = over the specified operating range. Supply voltages per normal operation conditions; see Test Loads for loading conditions
Parameter
Symbol
Conditions
Minimum
Typical Maximum Units Notes
Input Crossover Voltage - DIF_IN VCROSS
Cross over voltage
150
900
mV
1
Input Swing - DIF_IN
Input Slew Rate - DIF_IN
Input Leakage Current
Input Duty Cycle
VSWING
dv/dt
IIN
Differential value
Measured differentially
300
0.4
-5
mV
V/ns
μA
1
8
5
1,2
VIN = VDD , VIN =GND
dtin
Measurement from differential waveform
45
0
55
125
%
1
1
Input Jitter - Cycle to Cycle
JDIFIn
Differential measurement
ps
1 Guaranteed by design and characterization, not 100% tested in production.
2Slew rate measured through +/-75mV window centered around differential zero
Electrical Characteristics–SMBus
TAMB = over the specified operating range. Supply voltages per normal operation conditions; see Test Loads for loading conditions
Parameter
Symbol
VILSMB
VIHSMB
VOLSMB
IPULLUP
VDDSMB
tRSMB
Conditions
Minimum
Typical Maximum Units Notes
SMBus Input Low Voltage
SMBus Input High Voltage
SMBus Output Low Voltage
SMBus Sink Current
0.8
VDDSMB
0.4
V
V
2.1
at IPULLUP
at VOL
V
4
mA
V
Nominal Bus Voltage
2.7
3.6
1000
300
1
1
1
5
SCLK/SDATA Rise Time
SCLK/SDATA Fall Time
SMBus Operating Frequency
(Max VIL - 0.15V) to (Min VIH + 0.15V)
(Min VIH + 0.15V) to (Max VIL - 0.15V)
Maximum SMBus operating frequency
ns
ns
kHz
tFSMB
fMAXSMB
500
1 Guaranteed by design and characterization, not 100% tested in production.
2 Control input must be monotonic from 20% to 80% of input swing.
3 Time from deassertion until outputs are > 200mV.
4 DIF_IN input.
5 The differential input clock must be running for the SMBus to be active.
©2018 Integrated Device Technology, Inc
5
August 14, 2018