BURNDY
Compression
TYPE YS-L
HYLINK™ SPLICE
STANDARD BARREL
COPPER COMPRESSION
UL Listed 90° C,
600 Volts to 35 KV ◆
C-93
Features and Benefits
• Standard barrel length.
◊ Ideal for limited space applications while
providing ample barrel length for proper
crimp.
• Four (4) center conductor stops.
◊ Provides a center wire stop for proper
conductor insertion.
CONDUCTOR
DIMENSION
INSTALLATION TOOLING ◆
MECHANICAL
Y35, ◆ Y39,Y750,Y46*
DIE NUMBER COLOR
◆
DIE INDEX
& EMBOSSMENT LENGTH
WIRE
STRIP
CATALOG
NUMBER
***
MM2
Y1MRTC
Y2MR
MD6
OUR840
AWG
L
B
MD7-34R
(# CRIMPS)
CODE
Y2MR (1)
YS8C-L-BOX
8 str.
10
1.24
.44
W8CVT (1)
X8CRT (1)
X5CRT (1)
U8CRT (1)
RED
49
1/2"
7/8"
Y1MRTC (1)
YS6C-L BOX
YS5C-L BOX
6 str.
5 str.
––
16
1.75
1.90
.81
.81
Y2MR (1)
W5CVT (1)
UCRT (1)
BLUE
7 or 374
Y1MRTC (1)
Y2MR (2)
YS4C-L BOX
YS3C-L
4 str.
3 str.
2 str.
––
25
––
1.93
2.05
2.07
.81
.88
.88
W4CVT (1)
––
X4CRT (1)
––
U4CRT (1)
U3CRT (1)
U2CRT (1)
GRAY
WHITE
BROWN
8 or 346
7/8"
Y1MRTC (2)
Y1MRTC (2)
9
15/16"
15/16"
Y2MR (2)
YS2C-L BOX
W2CVT (1)
X2CRT (1)
10
Y1MRTC (2)
YS1C-L BOX
YS25-L BOX
YS26-L BOX
YS27-L BOX
YS28-L BOX
YS29-L BOX
YS30-L
1 str.
50
––
2.06
2.08
2.17
2.30
2.32
2.46
2.47
2.60
2.74
3.15
3.22
3.22
3.72
4.28
.88
Y1MRTC (2)
W1CVT (1)
W25VT (2)
W26VT (2)
W27VT (2)
W28VT (2)
W29VT (2)
W30VT (2)
W31VT (2)
W32VT (2)
W34VT (2)
––
X1CRT (1)
U1CRT-1 (1)
U25RT (1)
U26RT (1)
U27RT (1)
U28RT (1)
U29RT (1)
U30RT (2)
U31RT (2)
U32RT (2)
U34RT (2)
U36RT (2)
U38RT (2)
U39RT (2)
P44RT** (2)
GREEN
PINK
11 or 375
12 or 348
13
15/16"
15/16"
1"
1/0 str.
.88
––
––
––
––
––
––
––
––
––
––
––
––
––
X25RT (2)
2/0 str.
70
.94
X26RT (2)
BLACK
ORANGE
PURPLE
YELLOW
WHITE
RED
3/0 str.
95
1.00
1.00
1.06
1.06
1.12
1.19
1.38
1.38
1.38
1.62
1.88
X27RT (2)
14
1-1/16"
1-1/16"
1-1/8"
4/0 str.
––
X28RT (2)
15
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
700 kcmil
750 kcmil
1000 kcmil
120
150
185
––
––
––
––
––
––
––
––
––
––
16
17 or 298
18 or 324
19 or 470
20 or 299
22 or 472
400
1-1/8"
YS31-L
1-3/16"
1-1/4"
YS32-L
BLUE
YS34-L
240
300
––
BROWN
GREEN
PINK
1-7/16"
1-7/16"
1-7/16"
1-11/16"
1-15/16"
YS36-L
YS38-L
––
YS39-L
––
––
BLACK
WHITE
24
YS44-L
500
––
27
◆ See tooling section of this catalog for complete tool and die
listings.
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P44RT for use with Y46 HYPRESS™ only. PUADP-1
adaptor not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ The maximum size for the Y35 is 400 kcmil insulated code
cable.
◆ For applications greater than 2000 Volts consult cable