Pre-amplified/3V Excitation/Gauge
X3GM-3,X3GM-6 Data sheet
Features
3V excitation, Battery operation available
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Non-corrosive liquid measurable (X3GMC only)
Applications
Industrial instrumentation
Pressure switch, Pneumatic device
Medical device
.
.
.
.
.
.
.
.
Part number for ordering
X3 GM C - 3 0 5 0 KP G S R
Terminal leads direction (See Outline Diagram)
R :
Rated Pressure (Pa)
Length of the pressure port
3 : 3mm
6 : 6mm
Model
X3GM
Terminal leads configuration
S : Surface mount package
Available pressure media
Pressure type
G : Gauge (Positive pressure)
No mark : Non-corrosive gas only
C
: Non-corrosive gas and liquid
GV : Gauge (Negative pressure)
GW : Gauge (Bipolar pressure)
(Contact us about availability)
X3GM-3
Pressure type
Gauge pressure
X3GM-6
Model
Package configuration
Surface mount package, 3mm pressure port
Surface mount package, 6mm pressure port
Measurable pressure range (kPa)
Part number for ordering
100 100
X3GM-3100KPGWSR
X3GM-3100KPGVSR
X3GM-3050KPGSR
X3GM-3100KPGSR
X3GM-3200KPGSR
X3GM-3001MPGSR
X3GM-6100KPGWSR
X3GM-6100KPGVSR
X3GM-6050KPGSR
X3GM-6100KPGSR
X3GM-6200KPGSR
X3GM-6001MPGSR
0
100
50
0
0
0
0
100
200
1000
Specifications
Model/Rated pressure
100KPGW
100KPGV
050KPG
100KPG
200KPG
001MPG
Unit
Recommended operating conditions
Pressure type
Gauge pressure
100
1.020
100 100
100
1.020
100
50
0.510
100
1.020
100
200
2.040
200
1000
10.20
0 1000
kPa
kg/cm2
kPa
Rated pressure
Measurable pressure range
0
0
50
0
0
Pressure media
Excitation voltage
1
XFGM : Non-corrosive gas only, XFGMC : Non-corrosive gas and liquid
3.0 0.15
VDC
VDC
Absolute maximum rating
Maximum load pressure
Maximum excitation voltage
Operating temperature
Storage temperature
Twice of rated pressure
1.5times of rated pressure
6
10 80
20 100
Operating humidity
30 80 (No dew condensation)
RH
mA
Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25
)
Current consumption
Output impedance
Source current
less than 6
less than 10
less than 0.1
less than 1
2 (For the reference)
1.5
mA
mA
msec
V
V
V
Sink current
Mechanical response time
Full scale span voltage
Offset voltage 1.2
Full scale span voltage 1.2
Accuracy 1.2
0.5 0.075
2.0 0.075
5.0
FS/0 50
Note ; 1) Please consult us available when you choose the C models.
2) Excluding input voltage error.
1