TPS54162-Q1
www.ti.com
SLVSA32C –OCTOBER 2009–REVISED MAY 2010
1-A 60-V STEP-DOWN DC/DC CONVERTER WITH LOW QUIESCENT CURRENT
Check for Samples: TPS54162-Q1
1
FEATURES
•
Asynchronous Switch Mode Regulator
•
Programmable Overvoltage, Undervoltage
Output Monitor
•
3.6 V to 48 V Operating Range, Withstands
Transients up to 60 V
•
•
•
Thermal Sensing and Shutdown
Switch Current Limit Protection
•
•
•
•
•
•
•
•
•
•
•
1 A Maximum Load Current
50 µA Typical Quiescent Current
Short Circuit and Overcurrent Protection of
FET
200 kHz to 2.2 MHz Switching Frequency
0.8 V ± 1.5% Voltage Reference
•
•
Junction Temperature Range: –40°C to 150°C
20-Pin HTSSOP PowerPAD™ Package
High Voltage Tolerant Enable Input
Soft Start on Enable Cycle
APPLICATIONS
Slew Rate Control on Internal Power Switch
Low-Power Mode for Light Load Conditions
Programmable Delay for Power-On Reset
External Compensation for Error Amplifier
•
•
•
•
•
Qualified for Automotive Applications
Automotive Telematics
Navigation Systems
In-Dash Instrumentation
Reset Function Filter Time for Fast Negative
Transients
Battery Powered Applications
DESCRIPTION
The TPS54162 is a step-down switch-mode power supply with a voltage supervisor and an integrated NMOS
switching FET. Integrated input voltage line feed forward topology improves line transient regulation of the
voltage mode buck regulator. The regulator has a cycle-by-cycle current limit. The device also features
low-power mode operation under light load conditons which reduces the supply current to 50 µA (typical). By
pulling the EN pin low, the supply shutdown current is reduced to 1 µA (typical).
An open drain reset signal indicates when the nominal output drops below the reset threshold set by an external
resistor divider network. The output voltage start up ramp is controlled by a soft start capacitor. There is an
internal undervoltage shut down which is activated when the input supply ramps down to 2.6 V. The device is
protected during an overload condition on output by frequency fold back operation, and also has a thermal
shutdown protection.
TYPICAL APPLICATION
TYPICAL CONVERTER EFFICIENCY
90
D1
TPS54162
VReg
VIN
VIN
EN
VBATT
R12
RST
80
70
60
50
40
30
20
10
0
C1
R11
R10
VIN = 14 V
VIN = 7 V
RESET
BOOT
C3
D2
L
VReg
C4
PH
LPM
C7
R9
SYNC
R4
R5
R7
C6
Rslew
VSENSE
SS
C8
C5
VReg = 5 V
fsw = 500 kHz
L = 22 µH
C = 100 µF
Rslew = 30 kW
TA = 25°C
R6
R8
C2
COMP
RT/CLK
R1
R2
R3
RST_TH
Cdly
GND
OV_TH
0.05
0.25 0.5
ILoad - Load Current - A
0.75
1
Figure 1.
Figure 2.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2009–2010, Texas Instruments Incorporated