320W Single Output with PFC Function
SP-320 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Built-in fan speed control
Fixed switching frequency at 100KHz
3 years warranty
SPECIFICATION
MODEL
SP-320-3.3 SP-320-5 SP-320-7.5 SP-320-12 SP-320-13.5 SP-320-15 SP-320-24 SP-320-27 SP-320-36 SP-320-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
22A
15V
24V
27V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
55A
55A
40A
25A
20A
13A
11.7A
8.8A
6.7A
0 ~ 60A
181.5W
0 ~ 55A
275W
0 ~ 40A
300W
0 ~ 25A
300W
0 ~ 22A
297W
0 ~ 20A
300W
0 ~ 13A
312W
0 ~ 11.7A 0 ~ 8.8A
315.9W 316.8W
0 ~ 6.7A
321.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 220mVp-p 240mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
OUTPUT
3.14 ~ 3.63V 4.5 ~ 5.5V 6 ~ 9V
10 ~ 13.2V 12 ~ 15V
13.5 ~ 18V 20 ~ 26.4V 26 ~ 31.5V 32.4 ~ 39.6V 41 ~ 56V
2.0%
0.5%
1.0%
2.0%
0.5%
1.0%
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.3%
0.5%
1.0%
0.2%
0.5%
1.0%
0.2%
0.5%
1.0%
0.2%
0.5%
1.0%
0.2%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
1.5%
800ms, 50ms/230VAC
2500ms, 50ms/115VAC at full load
16ms/115VAC at full load
124 ~ 370VDC
16ms/230VAC
Note.5 88 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95/230VAC
PF>0.98/115VAC at full load
74%
79%
5A
83%
86%
86%
86%
87%
88%
87%
89%
INPUT
2.5A
115VAC
230VAC
AC CURRENT
(Typ.)
1.5A
2.5A
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
20A/115VAC
40A/230VAC
<1mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 45 ~ 52.5V 57.6 ~ 67.2V
OVERLOAD
3.8 ~ 4.5V 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
80 (70 3.3V,5V only) (TSW1 : detect on heatsink of power transistor)
PROTECTION OVER VOLTAGE
5
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
207K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
215*115*50mm (L*W*H)
1.1Kg; 12pcs/14Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-320-SPEC 2007-10-25