80W Constant Voltage+ Constant Current LED Driver
SLD-80 series
SPECIFICATION
MODEL
SLD-80-12
SLD-80-24
12V
24V
DC VOLTAGE
8.4~12V
6.6A
16.8 ~24V
3.3A
CONSTANT CURRENT REGION Note.2
RATED CURRENT
79.2W
Note.5
79.2W
240mVp-p
±3.0%
±0.5%
±0.5%
RATED POWER
150mVp-p
±4.0%
±0.5%
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE Note.4
LINE REGULATION
OUTPUT
±1.5%
LOAD REGULATION
500ms, 80ms 115VAC / 230VAC
SETUP, RISE TIME Note.6
10ms/230VAC
110~ 305VAC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
10ms/115VAC
155~ 431VDC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
Note.5
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 10%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
TOTAL HARMONIC DISTORTION
INPUT
EFFICIENCY (Typ.)
AC CURRENT
90.5%
0.9A / 115VAC
91.5%
0.45A / 230VAC
0.38A/277VAC
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
COLD START 50A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
8 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
<0.25mA / 277VAC
LEAKAGE CURRENT
NO LOAD POWER CONSUMPTION <0.5W
95 ~ 108%
Constant current limiting or Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
ENVIRONMENT
14 ~ 17V
28 ~ 34V
Shut down and latch off o/p voltage, re-power on to recover
Hiccup mode, recovers automatically after fault condition is removed
Tcase=-20 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Tcase=+90℃
20 ~ 95% RH non-condensing
-40 ~ +80℃
±0.03%/℃(0 ~ 50℃)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
OVER TEMPERATURE
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
UL8750(type”HL”),CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384,
EAC TP TC 004, GB19510.1,GB19510.14
SAFETY STANDARDS Note.8
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION Note.8
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
Standard
Test Level/Note
-----
-----
Class C @load≥60%
-----
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EN61000-3-2 ,GB/T17625.1
SAFETY &
EMC
EN61000-3-3
EMC IMMUNITY
Standard
EN61000-4-2
EN61000-4-3
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2
EFT/Burst
Surge
Conducted
Magnetic Field
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 2
1KV/Line-Line
Level 2
Level 2
>95% dip 0.5 periods, 30% dip 25 periods,
Voltage Dips and Interruptions
EN61000-4-11
>95% interruptions 250 periods
MTBF
DIMENSION
PACKING
867.33K hrs min. Telcordia SR-332 (Bellcore) ; 260.96K hrs min.
320*30*16.8mm (L*W*H)
0.206 Kg; 64pcs / 14.184Kg / 0.75CUFT
MIL-HDBK-217F (25℃)
OTHERS
NOTE
℃
℃
℃℃
File Name:SLD-80-SPEC 2019-09-16