SinglFuse™ SF-0603FPxxxF Series Features
nꢀ Singleꢀblowꢀfuseꢀforꢀovercurrentꢀprotection
nꢀ 1608ꢀ(EIAꢀ0603)ꢀminiatureꢀfootprint
nꢀ Fast-actingꢀprecisionꢀfuse
nꢀ ULꢀ248-14ꢀlisted
H
nꢀ RoHSꢀcompliant*ꢀandꢀhalogenꢀfree**
nꢀ Thinꢀfilmꢀchipꢀdesign
nꢀ Surfaceꢀmountꢀpackagingꢀforꢀautomatedꢀassembly
SF-0603FPxxxF Series - Fast Acting Precision Surface Mount Fuses
Electrical Characteristics
Rated Current
Resistance
(Ω) Typ.***
2.20
Rated
Voltage
Interrupting
Rating
Typical
I2t (A2s) ****
0.0006
Model
Fusing Time
(Amps)
0.15
0.20
0.25
0.375
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.50
3.00
3.50
4.00
5.00
SF-0603FP015F-2
SF-0603FP020F-2
SF-0603FP025F-2
SF-0603FP0375F-2
SF-0603FP050F-2
SF-0603FP075F-2
SF-0603FP100F-2
SF-0603FP125F-2
SF-0603FP150F-2
SF-0603FP175F-2
SF-0603FP200F-2
SF-0603FP250F-2
SF-0603FP300F-2
SF-0603FP350F-2
SF-0603FP400F-2
SF-0603FP500F-2
1.30
1.10
0.48
0.0014
0.0016
0.0040
0.0120
0.0210
0.0420
0.0520
0.0710
0.10
0.14
0.24
0.33
0.49
AC/DC 35 V 50 A
DC 65 V 13 A
0.185
0.112
0.069
0.048
0.037
0.031
0.026
0.021
0.0176
0.0148
0.0125
0.0095
DC 65 V
Open within 5
sec. at 200 %
rated current
AC/DC 35 V 35 A
DC 65 V 13 A
AC/DC 35 V 35 A
AC/DC 24 V 50 A
DC 35 V
0.63
1.10
***ꢀ Resistanceꢀvalueꢀmeasuredꢀwithꢀ≤10ꢀ%ꢀratedꢀcurrentꢀatꢀ25ꢀ°Cꢀambient.ꢀToleranceꢀ±25ꢀ%.
2
**** Melting I tꢀcalculatedꢀatꢀ0.001ꢀsecondꢀpre-arcingꢀtime.
Reliability Testing
No.
Test
Requirement
Test Condition
Test Reference
≤1ꢀA:ꢀDCRꢀchangeꢀ≤ꢀ±10ꢀ%
>1ꢀA:ꢀDCRꢀchangeꢀ≤ꢀ±20ꢀ%
ReferꢀtoꢀSTPꢀ
document
1
Bending
2 mm
MIL-STD-202
Methodꢀ208
2
3
4
5
6
7
Solderability
Minimumꢀ95ꢀ%ꢀcoverage
Oneꢀdipꢀatꢀ255ꢀ°Cꢀforꢀ5ꢀseconds
100ꢀcyclesꢀbetweenꢀ-55ꢀ°Cꢀandꢀ+125ꢀ°C
10ꢀcycles
DCRꢀchangeꢀ≤ꢀ±10ꢀ%
Noꢀmechanicalꢀdamage
MIL-STD-202
Methodꢀ107
Thermalꢀshock
Moistureꢀresistance
Saltꢀspray
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
Noꢀexcessiveꢀcorrosion
MIL-STD-202
Methodꢀ106
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
Noꢀexcessiveꢀcorrosion
MIL-STD-202
Methodꢀ101
48ꢀhourꢀexposure,ꢀ5ꢀ%ꢀsaltꢀsolution
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
Noꢀmechanicalꢀdamage
0.4ꢀinchꢀD.A.ꢀorꢀ30ꢀGꢀbetweenꢀ
5-3000 Hz
MIL-STD-202
Methodꢀ204
Mechanicalꢀvibration
Mechanicalꢀshock
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
Noꢀmechanicalꢀdamage
MIL-STD-202
Methodꢀ213
1500ꢀG,ꢀ0.5ꢀms,ꢀhalf-sineꢀshocks
Noꢀelectricalꢀ“opens”ꢀduringꢀtesting
Voltageꢀdropꢀchangeꢀshallꢀbeꢀlessꢀ
thanꢀ±10ꢀ%ꢀofꢀinitialꢀvalue
75ꢀ%ꢀratedꢀcurrentꢀforꢀ2000ꢀhoursꢀatꢀ
ambientꢀtemperatureꢀbetweenꢀ
+20ꢀ°Cꢀandꢀ+30ꢀ°C
ReferꢀtoꢀSTPꢀ
document
8
Life
Agency Recognition
*ꢀꢀꢀ RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincl.ꢀannexꢀ&ꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ
**ꢀ Bournsꢀconsidersꢀaꢀproductꢀtoꢀbeꢀ“halogenꢀfree”ꢀifꢀ(a)ꢀtheꢀBromineꢀ(Br)ꢀcontentꢀisꢀ900ꢀppmꢀorꢀꢀ
ULꢀFileꢀNumber .................................................... E198545
ꢀ
ꢀ
less;ꢀ(b)ꢀtheꢀChlorineꢀ(Cl)ꢀcontentꢀisꢀ900ꢀppmꢀorꢀless;ꢀandꢀ(c)ꢀtheꢀtotalꢀBromineꢀ(Br)ꢀandꢀChlorineꢀꢀ
(Cl)ꢀcontentꢀisꢀ1500ꢀppmꢀorꢀless.
“SinglFuse”ꢀisꢀaꢀtrademarkꢀofꢀBourns,ꢀInc.ꢀ
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Usersꢀshouldꢀverifyꢀactualꢀdeviceꢀperformanceꢀinꢀtheirꢀspecificꢀapplications.ꢀ
Theꢀproductsꢀdescribedꢀhereinꢀandꢀthisꢀdocumentꢀareꢀsubjectꢀtoꢀspecificꢀlegalꢀdisclaimersꢀasꢀsetꢀforthꢀ
onꢀtheꢀlastꢀpageꢀofꢀthisꢀdocument,ꢀandꢀatꢀwww.bourns.com/docs/legal/disclaimer.pdf.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov