SSwi8tchVMoKde P-oSwer SSupeplyries
240 W
A Perfect Fit for Small Control Panels
Coated PCBs for Better Resistance
to Environment
Connections for Easy Wiring
• Operation possible at ambient temperatures from -40 to 70°C.
• Side-by-side mounting possible (up to 55°C).
• Power Boost function at 150%.
Our shared Value Design for Panel (herein after referred to as Value Design) concept
for the specifications of products used in control panels will create new value to our
customer's control panels.
Combining multiple products that share the Value Design concept will further increase
the value provided to control panels.
Specifications
Ratings, Characteristics, and Functions
Power rating
240 W
24 V
Item
Output voltage
115 VAC input *1
230 VAC input *1
91% typ.
93% typ.
Efficiency
Voltage range *2
Frequency *2
Single-phase, 85 to 264 VAC, 90 to 350 VDC, 265 to 300 VAC (1 second)
50/60 Hz (47 to 63 Hz)
2.4 A typ.
115 VAC input *1
230 VAC input *1
Input current
1.3 A typ.
Input
Power factor
0.9 min.
115 VAC input
230 VAC input
115 VAC input
230 VAC input
0.5 mA max.
1 mA max.
Leakage current *3
16 A typ.
Inrush current (for a
cold start at 25°C)
32 A typ.
Rated output current
10 A
Rated output electric power
Maximum boost current
240 W
15 A
Voltage adjustment range *4
21.6 to 28 V (with V.ADJ)
1000 ms max.
1000 ms max.
35 ms typ.
Output
115 VAC input *1
Start up time
230 VAC input *1
115 VAC input *1
230 VAC input *1
Hold time *5
35 ms typ.
Overload protection
Overvoltage protection
Output indicator
Yes, automatic reset
Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on
the input again)
Additional
functions
Yes (LED: Green)
Low-voltage detection output
Yes (Photoswitch output: 30 VDC max., 50 mA max.)
3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA
Withstand voltage
Insulation
500 VAC for 1 min (between all output terminals and all low-voltage detection output terminals),
current cutoff 10 mA
100 MΩ min. (between all output terminals/all low-voltage detection output terminals and all input
terminals/PE terminals) at 500 VDC
Insulation resistance
Vibration resistance
Shock resistance
10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions
150 m/s2, 3 times each in X, Y, Z directions
700 g max.
Environment
Construction Weight
*1. The value is when both rated output voltage and rated output current are satisfied.
*2. Do not use an inverter output for the product. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the product may result in ignition or burning.
If the input is connected to a UPS, do not connect a UPS with a square-wave output.
Doing so will cause the internal temperature of the product to increase, possibly causing smoking or burning.
*3. The value for the leakage current is determined according to the Electrical Appliances and Material Safety Act.
*4. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 28 V min of the voltage adjustment range. When
adjusting the output voltage, confirm the actual output voltage from the product and be sure that the load is not damaged.
*5. A characteristic when the ambient operating temperature of 25°C.
For details, refer to the website. (http://www.ia.omron.com/)