General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1-AP
n
n
n
n
n
1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
Sensitive coil 400mW
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C
WG version: product in accordance to IEC 60335-1
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
F0144-C
V Z b
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Coil Data
Coil voltage range
5 to 110VDC
Operative range, IEC 61810
Coil insulation system according UL
2
class F
Contact Data
Contact arrangement
12A
16A
1 form C (CO) or 1 form A (NO)
Coil versions, DC coil
Rated voltage
Max. switching voltage
Rated current
250VAC
400VAC
Coil
code
Rated
voltage
VDC
5
6
9
12
24
48
Operate
voltage
VDC
3.5
4.2
6.3
8.4
16.8
33.6
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
Coil
resistance
Ω 10%
62
90
200
360
1440
5520
Rated coil
power
mW
12A
12A
16A
Limiting continuous current
Limiting making current
max. 4s, duty factor 10%
Breaking capacity max.
Contact Material
Frequency of operation, with/without load
Operate/release time max., DC coil
Bounce time max., DC coil, form A/form B
16A, UL: 20A
005
006
009
012
024
048
403
400
400
400
400
417
25A
3000VA
30A
4000VA
AgNi 90/10
360/72000h-1
8/6ms
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
4/6ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RT314 DC-coil A (NO)
RT314 DC-coil C (CO)
RT314 DC-coil A (NO)
RT114 DC-coil A (NO)
RT114 AC-coil A (NO)
UL 508
RT314
RT334
RT314
16A, 250VAC, cosφ=1, 85°C
16A, 250VAC, cosφ=1, 85°C
10A, 400VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 70°C
30x103
10x103
150x103
50x103
100x103
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103
A (NO)
A (NO)
16A, 250VAC, gen. purpose, 85°C
1hp, 240VAC, 40°C
50x103
1x103
EN60947-5-1
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
EN60730-1
RT314 DC-coil A (NO)
Mechanical endurance
12(2)A, 250VAC, 85°C
>30x106 operations
100x103
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
1000Vrms
5000Vrms
between contact and coil
Material group of insulation parts
Tracking index of relay base
≥10/10mm
IIIa
PTI 250V
1
04-2011, Rev. 0411
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company