General Purpose Relays
Power PCB Relay RT1
I
I
I
I
I
I
I
1 pole 12 / 16 A, 1 CO or 1 NO contact
DC- or AC-coil
Sensitive coil 400 mW
5 kV / 10 mm coil-contact, reinforced insulation
Ambient temperature 85°C (DC-coil)
WG version: Product in accordance to IEC60335-1
RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
Applications
F0144-B
Boiler control, timers, garage door control, POS automation,
interface modules
Approvals
V
REG.-Nr. 6106,
Z
E214025,
B
C0786,
S
0039110/01-02,
FFI 190164 A1,
H
98.4118.01
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Limiting continuous current
Maximum breaking capacity AC
Limiting making capacity, max 4 s, df 10%
Contact material
1 CO or 1 NO contact
single contact
micro disconnection
12 A
16 A
240/400 VAC
UL: 20 A
4000 VA
30 A
3000 VA
25 A
AgNi 90/10, AgNi 90/10 gold plated
Mechanical endurance DC coil
AC coil
Rated frequency of operation with / without load
> 30 x 106 cycles
> 10 x 106 cycles
6 / 1200 min-1
Contact ratings
Type
Load
Cycles
RT314 16 A, 250 VAC, NO contact, 85°C, DF 10%, UL508
RT314 16 A, 250 VAC, NC contact, 70°C, 30min-1
RT314 20 A, 250 VAC, NO contact, 85°C, UL508
RT314 1000 W incandescent lamp, 250 VAC
50x103
53x103
6x103
1.2x103
200x103
1.1x106
RT314 10 A, 250 VAC, cosϕ=0.6, CO contact, 70°C
RT314 5 A / 2 A, 250 VAC, cosϕ=1, motor, NO contact, 10min-1, 70°C
RT314 0.26 A / 0.01 A, 230 VAC, cosϕ=0.38, valve, NO contact, 25min-1 7.6x106
RT314 Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
RT314 1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
RT314 AC15, 6 A, 250 VAC, NO and NC contact, 85°C, EN60947-5-1
RT314 DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85°C, EN60947-5-1
Coil data
Rated coil voltage range DC coil
AC coil
5...110 VDC
24...230 VAC
typ 400 mW
typ 0.75 VA
2
Coil power DC coil
AC coil
Operative range
Coil insulation system according UL1446
class F
1
Datasheet
Rev. EK1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2005/11
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.