General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1 bistable
n
n
n
n
1 pole 16A, 1 form C (CO) or 1 form A (NO) contact
Polarized bistable version with 1 or 2 coils
5kV/10mm coil-contact
Reinforced insulation
Typical applications
Battery powered equipment or applications with “memory function”
F0176-C
V Z b
Approvals
Coil Data, bistable coils
Magnetic system
Coil voltage range
Operative range, IEC 61810
Limiting voltage, % of rated coil voltage 120%
Min./Max. energization duration
1 coil
2 coils
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
polarized, bistable
3 to 24VDC
2
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
150%
1 form C (CO) or 1 form A (NO)
30ms/1min at <10% duty factor
250VAC
400VAC
16A
Coil insulation system according UL1446
class F
Coil versions, bistable coil
Limiting continuous current
Limiting making current, max. 4s, duty factor 10% 30A
Breaking capacity max.
Contact material
Frequency of operation, with/without load
Operate/Reset time max.
Bounce time max., form A/form B
16A, UL: 20A
Coil
code
Rated
voltage
VDC
Set
voltage
VDC
Reset
voltage
VDC
Coil
resistance
Ω 10%
Rated coil
power
mW
4000VA
AgNi 90/10
360/72000h-1
10/10ms
bistable 1 coil
A03
A05
A06
A12
A24
3
5
6
12
24
2.1
3.5
4.2
8.4
16.8
1.7
2.8
3.3
6.6
13.2
21
62
90
360
1440
429
403
400
400
400
3/6ms
Contact ratings
Type
Contact
Load
Cycles
bistable 2 coils
IEC 61810
RT314
RT314
UL 508
RT314
RT334
RT314
F03
F05
F06
F12
F24
3
5
6
12
24
2.1
3.5
4.2
8.4
16.8
1.7
2.8
3.3
6.6
13.2
15
42
55
240
886
600
595
655
600
650
A (NO)
C (CO)
16A, 250VAC resistive, 85°C
16A, 250VAC resistive, 85°C
30x103
10x103
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C
A (NO)
A (NO)
6x103
50x103
1x103
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
16A, 250VAC, general purpose, 85°C
1hp, 240VAC, 40°C
Bistable coils - operation
Version
Mechanical endurance
>5x106 operations
1 coil
2 coils
Coil terminals
Operate
Reset
A1 A2
A1 A3 A2
+
-
-
+
+
+
-
-
Contact position not defined at delivery
1
06-2013, Rev. 0613
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2013 Tyco Electronics Corporation,