EMC/EMI Chokes
RN series
Current-compensated Chokes
n Rated currents from 0.3 to 10A
Approvals
n DC to 1kHz frequency
n 100kHz to 3MHz common-mode
resonance frequency
n Dual-choke configurations
n Multiple PCB-mounting options
VDE: excluding RN 102, RN 202
Technical specifications
Typical electrical schematic
Maximum continuous operating voltage:
Operating frequency:
250VAC @ 40°C
dc to 1kHz
Rated currents:
0.3 to 10A @ 40°C max.
High potential test voltage
winding-to-winding @ 25°C:
1500VAC, 60 sec, guaranteed
1500V, 50Hz, 2 sec, factory test
4000VAC, 60 sec, guaranteed
20 x Inominal @ 25°C
winding-to-housing @ 25°C:
Surge current @ 10msec:
Temperature range (operation and storage):
Flammability corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
-40°C to +125°C (40/125/56)
UL 94V-0
> 5,000,000 hours
Features and benefits
Typical applications
RN chokes are attenuating common-mode or
asymmetric (P/N –> E) interference signals,
by being connected in series with the phase
and neutral lines of an AC powerline input.
Symmetrical components of the noise are
also attenuated by the leakage inductance of
the windings. These chokes are typically used
in conjunction with suppression capacitors.
n
High saturation resistance and excellent
thermal behavior.
n
Phase-angle control circuits in combination
with saturating chokes
n
n
n
n
n
Through hole pin connections.
Dual-choke configuration.
Small compact design.
n
n
EMI input filters
For suppressing equipment with no earth
connection
Multiple housing options.
Custom-specific versions are available on
request.
n
Suppressing high interference levels