General Purpose Relays
Industrial Relays
SCHRACK
Power Relay RM 2/3/7
n
n
n
n
n
n
2/3 pole 10/16A, 2 form C (CO) or 3 form C (CO) contacts
Switching capacity up to 6000VA
DC or AC coil
Mechanical indicator
Push-to-test button
Plug-in version, PCB terminals, chassis- or DIN-rail mount
Typical applications
Elevator control, power supplies
F0163-B
Z
Approvals
VDE REG.-Nr. 40003144, UL E214025
Technical data of approved types on request
Coil Data
Coil voltage range
6 to 220VDC
6 to 400VAC
2
Operative range, IEC 61810
Contact Data
Contact arrangement
RM2
2 form C
2 CO
RM3
3 form C
3 CO
RM7
3 form C
3 CO
Coil insulation system according UL
class 130 (B)
Coil versions, DC coil
Rated voltage
Max. switching voltage
Rated current
400VAC
440VAC
10A
Coil code
Rated
voltage
VDC
Coil
Rated coil
power
W
STD
LED
bipolar
PD3)
LED+
PD3)
resistance
16A
16A
40A
Ω 10ꢀ1)2)
Limiting making current, max. 20ms 40A
40A
Coil versions, DC coil, RM2, RM3
Switching power
Contact material
6000VA
ACdO,
AgNi90/10
3800VA
AgCdO,
6000VA
AgCdO
006
012
024
048
060
110
221
L06
L12
L24
L48
L60
M10
N21
0A6
0B2
0C4
0E8
0G0
1B0
2C1
LA6
LB2
LC4
LE8
LG0
MB0
NC1
6
12
24
48
60
110
220
32
110
475
2000
2850
100001)
400002)
1.1
1.3
1.2
1.2
1.3
1.2
1.2
in preparation
Min. recommended contact load
Frequency of operation, with/without load
Operate/release time max., DC coil
24VDC/100mA
960/6000h-1
15/10ms
Bounce time max., DC coil, form A/form B
4/10ms
Coil versions, DC coil, RM7
Contact ratings
006
012
024
048
060
110
221
L06
L12
L24
L48
L60
M10
N21
0A6
0B2
0C4
0E8
0G0
1B0
2C1
LA6
LB2
LC4
LE8
LG0
MB0
NC1
6
12
24
48
60
110
220
24
86
345
1340
2200
7300
300002)
1.5
1.7
1.7
1.7
1.6
1.7
1.6
Type
Contact
Load
Cycles
IEC 61810
RM20 C (CO)
RM22 C (CO)
RM22 C (CO)
RM30 C (CO)
RM70 C (CO)
UL 508
16A, 400VAC, cosφ=1, 35°C
100x103
100x103
50x103
16A, 400VAC, cosφ=1, DC-coil, 70°C
16A, 400VAC, cosφ=1, AC-coil, 60°C
10A, 400VAC, cosφ=1, 35°C
100x103
100x103
16A, 400VAC, cosφ=1, 35°C
Operate voltage, DC coil
Release voltage, DC coil
1) Coil resistance 12ꢀ, 2) Coil resistance 15ꢀ
3) Protection diode PD; standard polarity: +A1 / -A2
75ꢀ of rated coil voltage
10ꢀ of rated coil voltage
RM2
RM2
A (NO)
A (NO)
16A, 277VAC, general purpose, 50°C
16A, 415VAC, resistive, 50°C
10A, 48VDC, 50°C
30x103
100x103
30x103
All figures are given for coil without pre-energization, at ambient temperature +23°C
RM20 A (NO)
RM3 C (CO)
RM30 A (NO)/B (NC) 10A, 277VAC, general purpose, 50°C
10A, 415VAC, resistive, 50°C
100x103
30x103
RM7
RM7
A (NO)
16A, 415VAC, resistive, 50°C
100x103
30x103
A (NO)/B (NC) 16A, 277VAC, general purpose, 50°C
Mechanical endurance
DC coil
AC coil
20x106 operations
20x106 operations
1
10-2012, Rev. 1012
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company