SPECIFICATION
MODEL
RD-85A
RD-85B
OUTPUT�NUMBER
DC�VOLTAGE
CH1
5V
CH2
12V
CH1
CH2
5V
24V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
8A
4A
8A
2A
Note.6 2�~�10A
Note.6 88W
0.3�~�5A
2�~�10A
88W
0.3�~�2.5A
RIPPLE�&�NOISE�(max.) Note.2 80mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 2.0%
120mVp-p
80mVp-p
CH1: 4.75�~�5.5V
2.0%
120mVp-p
OUTPUT
CH1: 4.75�~�5.5V
5.0%
1.0%
3.0%
5.0%
1.0%
3.0%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
Note.4 0.5%
Note.5 1.0%
0.5%
1.0%
500ms,�20ms/230VAC����������1200ms,�30ms/115VAC at�full�load
160ms/230VAC����������18ms/115VAC at�full�load
VOLTAGE�RANGE
88�~�264VAC����������125�~�373VDC (Withstand�300VAC�surge�for�5sec.�Without�damage)
47�~�63Hz
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
78%
80%
INPUT
2.5A/115VAC����������1.5A/230VAC
COLD�START 40A/230VAC
<2mA /�240VAC
110�~�150% rated�output�power
OVER�LOAD
Protection�type�:�Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
CH1:�5.75�~�6.75V
PROTECTION
OVER�VOLTAGE
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-25�~�+70 (Refer�to�output�load�derating�curve)
20�~�90%�RH non-condensing
WORKING�TEMP.
WORKING�HUMIDITY
-40�~�+85 ,�10�~�95%�RH
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.03%/ (0�~�50 )on�+5V�output
VIBRATION
10�~�500Hz,�5G�10min./1cycle,�period�for 60min.�each�along�X, Y,�Z�axes
UL60950-1, TUV�EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND�VOLTAGE
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
Compliance�to�EN55022�(CISPR22)�Class�B
Compliance�to EN61000-3-2,-3
SAFETY &
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
EMC
(Note�7)
Compliance�to�EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN61000-6-2�(EN50082-2)�heavy�industry�level,�criteria A
MTBF
239.4Khrs�min.������MIL-HDBK-217F�(25
159*97*38mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
0.6Kg;�24pcs/15.4Kg/0.7CUFT
PACKING
�ꢀꢁꢂꢃꢃꢁꢄꢅꢆꢅꢇꢈꢉꢈꢆꢊꢁꢋꢌꢍꢁꢊꢄꢈꢎꢏꢅꢃꢃꢐꢁꢇꢈꢑꢉꢏꢒꢑꢈꢓꢁꢅꢆꢈꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢅꢉꢁꢕꢖꢗꢘꢂꢙꢁꢏꢑꢄꢔꢉꢚꢁꢆꢅꢉꢈꢓꢁꢃꢒꢅꢓꢁꢅꢑꢓꢁꢕꢛ ꢒꢜꢁꢅꢇꢝꢏꢈꢑꢉꢁꢉꢈꢇꢄꢈꢆꢅꢉꢔꢆꢈꢀ
ꢕꢀꢁꢞꢏꢄꢄꢃꢈꢁꢟꢁꢑꢒꢏꢊꢈꢁꢅꢆꢈꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢅꢉꢁꢕꢗꢠꢡꢢꢁꢒꢜꢁꢝꢅꢑꢓꢣꢏꢓꢉꢤꢁꢝꢐꢁꢔꢊꢏꢑꢥꢁꢅꢁ�ꢕꢦꢁꢉꢣꢏꢊꢉꢈꢓꢁꢄꢅꢏꢆꢧꢣꢏꢆꢈꢁꢉꢈꢆꢇꢏꢑꢅꢉꢈꢓꢁꢣꢏꢉꢤꢁꢅꢁꢗꢀ�ꢔꢜꢁꢟꢁꢨꢩꢔꢜꢁꢄꢅꢆꢅꢃꢃꢈꢃꢁꢎꢅꢄꢅꢎꢏꢉꢒꢆꢀ
ꢖꢀꢁꢍꢒꢃꢈꢆꢅꢑꢎꢈꢁꢪꢁꢏꢑꢎꢃꢔꢓꢈꢊꢁꢊꢈꢉꢁꢔꢄꢁꢉꢒꢃꢈꢆꢅꢑꢎꢈꢚꢁꢃꢏꢑꢈꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢁꢅꢑꢓꢁꢃꢒꢅꢓꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢀ
ꢨꢀꢁꢫꢏꢑꢈꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢁꢏꢊꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢜꢆꢒꢇꢁꢃꢒꢣꢁꢃꢏꢑꢈꢁꢉꢒꢁꢤꢏꢥꢤꢁꢃꢏꢑꢈꢁꢅꢉꢁꢆꢅꢉꢈꢓꢁꢃꢒꢅꢓꢀ
ꢛꢀꢁꢫꢒꢅꢓꢁꢆꢈꢥꢔꢃꢅꢉꢏꢒꢑꢁꢏꢊꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢜꢆꢒꢇꢁꢕꢗꢬꢁꢉꢒꢁ�ꢗꢗꢬꢁꢆꢅꢉꢈꢓꢁꢃꢒꢅꢓꢚꢁꢅꢑꢓꢁꢒꢉꢤꢈꢆꢁꢒꢔꢉꢄꢔꢉꢁꢅꢉꢁꢭꢗꢬꢁꢆꢅꢉꢈꢓꢁꢃꢒꢅꢓꢀ
ꢭꢀꢁꢮꢅꢎꢤꢁꢒꢔꢉꢄꢔꢉꢁꢎꢅꢑꢁꢣꢒꢆꢯꢁꢣꢏꢉꢤꢏꢑꢁꢎꢔꢆꢆꢈꢑꢉꢁꢆꢅꢑꢥꢈꢀꢁꢰꢔꢉꢁꢉꢒꢉꢅꢃꢁꢒꢔꢉꢄꢔꢉꢁꢄꢒꢣꢈꢆꢁꢎꢅꢑꢱꢉꢁꢈꢲꢎꢈꢈꢓꢁꢆꢅꢉꢈꢓꢁꢒꢔꢉꢄꢔꢉꢁꢄꢒꢣꢈꢆꢀ
ꢩꢀꢁꢍꢤꢈꢁꢄꢒꢣꢈꢆꢁꢊꢔꢄꢄꢃꢐꢁꢏꢊꢁꢎꢒꢑꢊꢏꢓꢈꢆꢈꢓꢁꢅꢁꢎꢒꢇꢄꢒꢑꢈꢑꢉꢁꢣꢤꢏꢎꢤꢁꢣꢏꢃꢃꢁꢝꢈꢁꢏꢑꢊꢉꢅꢃꢃꢈꢓꢁꢏꢑꢉꢒꢁꢅꢁꢜꢏꢑꢅꢃꢁꢈꢳꢔꢏꢄꢇꢈꢑꢉꢀꢁꢍꢤꢈꢁꢜꢏꢑꢅꢃꢁꢈꢳꢔꢏꢄꢇꢈꢑꢉꢁꢇꢔꢊꢉꢁꢝꢈꢁꢆꢈꢧꢎꢒꢑꢜꢏꢆꢇꢈꢓꢁꢉꢤꢅꢉꢁꢏꢉꢁꢊꢉꢏꢃꢃꢁꢇꢈꢈꢉꢊ
ꢮꢠꢙꢁꢓꢏꢆꢈꢎꢉꢏꢴꢈꢊꢀ
ꢵꢀꢁꢫꢈꢑꢥꢉꢤꢁꢒꢜꢁꢊꢈꢉꢁꢔꢄꢁꢉꢏꢇꢈꢁꢏꢊꢁꢇꢈꢅꢊꢔꢆꢈꢓꢁꢅꢉꢁꢎꢒꢃꢓꢁꢜꢏꢆꢊꢉꢁꢊꢉꢅꢆꢉꢀꢁꢍꢔꢆꢑꢏꢑꢥꢁꢌꢋꢶꢌꢷꢷꢁꢉꢤꢈꢁꢄꢒꢣꢈꢆꢁꢊꢔꢄꢄꢃꢐꢁꢴꢈꢆꢐꢁꢳꢔꢏꢎꢯꢃꢐꢁꢇꢅꢐꢁꢃꢈꢅꢓꢁꢉꢒꢁꢏꢑꢎꢆꢈꢅꢊꢈꢁꢒꢜꢁꢉꢤꢈꢁꢊꢈꢉꢁꢔꢄꢁꢉꢏꢇꢈꢀ
300 Myles Stanꢁish Blvꢁ., Taunton, MA 02780
WWW.ASTrOdYNE.COM
Ph: 1-800-823-8082
Fax: 508-823-8181