● Universal Input 80-264VAC or 115-370VDC
● Operating Temperature Range of -25°C to +85°C
● Isolated Output 3kVAC / 1 min
● Short Circuit and Overcurrent Protection
● Low Output Ripple & Noise
POWERLINE
AC/DC-Converter
with 3 year Warranty
Features
Regulated
Converters
● Low Cost AC/DC Power Supply
● EN, UL and CE certified
The ultra-compact wired RAC04-C/W modules are available with output voltages of 3.3,
5, 9, 12, 15, and 24V, and the input-to-output isolation is approximately 3kVAC/1min.
With a standby consumption of 100mW typical, the mini power supplies are particularly
suitable for energy-saving sleep mode and standby applications. Because of its compact
design (height <17 mm), it is a versatile solution for home automation and other similar
applications. Complete with an integrated input filter, the series has enhanced EMI
performance and complies with EN55022, class B. The mini power supplies are also
protected against short circuit with fully automatic restart after the error has been solved.
The converters are EN/UL60950-1 certified and come complete with a 3 year warranty.
Description
4 Watt
Single
Output
Selection Guide
Part
Number
Input
Voltage
(VAC)
Output
Voltage
(VDC)
3.3
Output
Current max.
(mA)
Efficiency
Typ.
Capacitive
Load
max.
(%)
67
RAC04-3.3SC/W
RAC04-05SC/W
RAC04-09SC/W
RAC04-12SC/W
RAC04-15SC/W
RAC04-24SC/W
80-264
1200
3000µF
80-264
80-264
80-264
80-264
80-264
5
800
444
333
267
167
72
76
77
77
79
1600µF
850µF
150µF
100µF
82µF
9
12
15
24
RoHS
2011/65/EU
6/6
E224736
Specifications (measured at TA 25°C, nominal input voltage, full load after warm-up)
EN-60950-1 Certified
IEC-60950-1 Certified
UL-60950-1 Certified
Input Voltage Range (with Derating)
Input Frequency (for AC Input)
Input Current (Full Load)
Inrush Current
80-264VAC or 115-370VDC
47-63Hz
115VAC / 230VAC
115VAC / 230VAC
80-264VAC
110mA / 72mA max.
30A / 60A max.
100mW typ. / 200mW max.
3.3V-24V
No Load Power Consumption
Output Voltage (Vout nom.)
Output Current Range
RAC04-C/W
167mA - 1200mA
4W max.
Rated Output Power
Output Voltage Tolerance
Minimum Load
2ꢀ typ. / 5ꢀ max.
0ꢀ
Output Ripple & Noise
Line Voltage Regulation
Load Voltage Regulation
Over Load Protection
Over Voltage Category
Leakage Current
(Full Load)115VAC / 230VAC @ 20MHz limited
LL-HL at full Load
200mVp-p max.
0.5ꢀ typ. / 1ꢀ max.
1.5ꢀ typ. / 5ꢀ max.
105ꢀ - 155ꢀ
OVC II
Derating-Graph
(Ambient Temperature)
10ꢀ-100ꢀ Load
120
100
0.85µxA max.
80
75
Operating Frequency
Isolation Voltage
Full Load
Input-Output
Input-Output
Input-Output
40kHz typ.
Safe Operating Area
60
3kVAC / 1 minute
1G Ω min.
50
25
Isolation Resistance
Isolation Capacitance
Short Circuit Protection
40
1000pF typ.
20
0
-25
-20
Hiccup, Auto Restart
-20°C to +60°C
-25°C to +85°C
-40°C to +100°C
UL94V-0 black plastic
Silicone
Operating Temperature Range
natural convection, without derating
natural air convection, with derating
0
20
40
60 70 80 100
85
Storage Temperature Range
Case Material
Ambient Temperature Range (°C)
Potting Material
Relative Humidity
Package Weight
95ꢀ RH max.
32g typ.
continued on next page
PA-18
REV: 0/2015
www.recom-power.com