5秒后页面跳转
R3-NL1-K3/Q PDF预览

R3-NL1-K3/Q

更新时间: 2022-05-14 22:22:22
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
5页 152K
描述
Remote I/O R3 Series LonWorks INTERFACE MODULE

R3-NL1-K3/Q 数据手册

 浏览型号R3-NL1-K3/Q的Datasheet PDF文件第2页浏览型号R3-NL1-K3/Q的Datasheet PDF文件第3页浏览型号R3-NL1-K3/Q的Datasheet PDF文件第4页浏览型号R3-NL1-K3/Q的Datasheet PDF文件第5页 
MODEL: R3-NL1  
Remote I/O R3 Series  
RELATED PRODUCTS  
• XIF File (Device Interface File)  
XIF file is used to define a LonWorks device when  
programmed on LonMaker.  
LonWorks INTERFACE MODULE  
(analog I/O 16 points, discrete I/O 48 points)  
27.5 (1.08)  
GENERAL SPECIFICATIONS  
Connection  
LonWorks: Euro type connector terminal  
130  
(5.12)  
(applicable wire size: 0.2 to 2.5 mm , stripped length 7 mm)  
2
Internal bus: Via the Installation Base  
(model: R3-BSx)  
Internal power: Via the Installation Base (model: R3-BSx)  
Power input, RUN contact output: M3 separable screw  
terminal (torque 0.5 N·m)  
109  
(4.29)  
mm (inch)  
Screw terminal: Nickel-plated steel  
Isolation: LonWorks to internal bus or internal power to  
power input to RUN contact output to FG  
Input error data setting: Input value setting at input module  
error with side DIP SW  
MODEL: R3–NL1–[1][2]  
ORDERING INFORMATION  
• Code number: R3-NL1-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-NL1-R/Q)  
Dual communication setting: Set with the side DIP switch  
Data allocation setting: Set with the side DIP switch  
RUN indicator: Bi-color (green/red) LED; Green ON in  
communications with another device online or changing the  
output data (turns off after 25 seconds of no  
communication); Red ON when receiving data (function  
selected with DIP SW)  
• Specify the specification for option code /Q  
(e.g. /C01)  
[1] POWER INPUT  
N: No power supply  
ERR indicator: Bi-color (green/red) LED; Green ON or  
blinking at communication error; Red ON at transmitting  
data (Function selected with DIP SW)  
AC Power  
K3: 100 – 120 V AC  
RUN CONTACT OUTPUT  
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *  
L3: 200 – 240 V AC  
RUN contact: Turns on while the green RUN LED is ON  
(LonWorks in normal communication)  
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *  
DC Power  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
R: 24 V DC  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *  
* Not selectable for use with independent power modules or  
network modules with the internal power input options.  
Mechanical life: 2 × 10 cycles (rate 300 cycles/min.) When  
7
driving an inductive load, external contact protection and  
noise quenching recommended.  
[2] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
LonWorks COMMUNICATION  
Neuron Chip: FT3120 (NeuronID printed in numbers and bar  
code [peel-off code 39 format])  
Transceiver: FT-X1 (equivalent to FTT10A)  
Transmission speed: 78 kbps  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Twisted-pair cable  
/C02: Polyurethane coating  
Distance, free topology: 500 meters  
Max. 64 nodes/channel  
/C03: Rubber coating  
LNS: Ver. 3.0 Service Pack 8 or higher  
Network variable type  
R3-NL1 SPECIFICATIONS  
ES-8427 Rev.10 Page 1/5  
http://www.m-system.co.jp/  

与R3-NL1-K3/Q相关器件

型号 品牌 描述 获取价格 数据表
R3-NL1-L3 MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格

R3-NL1-L3/Q MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格

R3-NL1-R MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格

R3-NL1-R/Q MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格

R3-NL2 MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格

R3-NL2-K3 MSYSTEM Remote I/O R3 Series LonWorks INTERFACE MODULE

获取价格