MODEL: R3-NL1
Remote I/O R3 Series
RELATED PRODUCTS
• XIF File (Device Interface File)
XIF file is used to define a LonWorks device when
programmed on LonMaker.
LonWorks INTERFACE MODULE
(analog I/O 16 points, discrete I/O 48 points)
27.5 (1.08)
GENERAL SPECIFICATIONS
Connection
LonWorks: Euro type connector terminal
130
(5.12)
(applicable wire size: 0.2 to 2.5 mm , stripped length 7 mm)
2
Internal bus: Via the Installation Base
(model: R3-BSx)
Internal power: Via the Installation Base (model: R3-BSx)
Power input, RUN contact output: M3 separable screw
terminal (torque 0.5 N·m)
109
(4.29)
mm (inch)
Screw terminal: Nickel-plated steel
Isolation: LonWorks to internal bus or internal power to
power input to RUN contact output to FG
Input error data setting: Input value setting at input module
error with side DIP SW
MODEL: R3–NL1–[1][2]
ORDERING INFORMATION
• Code number: R3-NL1-[1][2]
Specify a code from below for each of [1] and [2].
(e.g. R3-NL1-R/Q)
Dual communication setting: Set with the side DIP switch
Data allocation setting: Set with the side DIP switch
RUN indicator: Bi-color (green/red) LED; Green ON in
communications with another device online or changing the
output data (turns off after 25 seconds of no
communication); Red ON when receiving data (function
selected with DIP SW)
• Specify the specification for option code /Q
(e.g. /C01)
[1] POWER INPUT
N: No power supply
ERR indicator: Bi-color (green/red) LED; Green ON or
blinking at communication error; Red ON at transmitting
data (Function selected with DIP SW)
AC Power
K3: 100 – 120 V AC
■ RUN CONTACT OUTPUT
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *
L3: 200 – 240 V AC
RUN contact: Turns on while the green RUN LED is ON
(LonWorks in normal communication)
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *
DC Power
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
R: 24 V DC
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *
* Not selectable for use with independent power modules or
network modules with the internal power input options.
Mechanical life: 2 × 10 cycles (rate 300 cycles/min.) When
7
driving an inductive load, external contact protection and
noise quenching recommended.
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
LonWorks COMMUNICATION
Neuron Chip: FT3120 (NeuronID printed in numbers and bar
code [peel-off code 39 format])
Transceiver: FT-X1 (equivalent to FTT10A)
Transmission speed: 78 kbps
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Twisted-pair cable
/C02: Polyurethane coating
Distance, free topology: 500 meters
Max. 64 nodes/channel
/C03: Rubber coating
LNS: Ver. 3.0 Service Pack 8 or higher
Network variable type
R3-NL1 SPECIFICATIONS
ES-8427 Rev.10 Page 1/5
http://www.m-system.co.jp/