Remote I/O R3 Series MODBUS INTERFACE MODULE

R3-NM1-K3/Q 数据手册

 浏览型号R3-NM1-K3/Q的Datasheet PDF文件第2页浏览型号R3-NM1-K3/Q的Datasheet PDF文件第3页浏览型号R3-NM1-K3/Q的Datasheet PDF文件第4页浏览型号R3-NM1-K3/Q的Datasheet PDF文件第5页浏览型号R3-NM1-K3/Q的Datasheet PDF文件第6页浏览型号R3-NM1-K3/Q的Datasheet PDF文件第7页 
MODEL: R3-NM1  
Remote I/O R3 Series  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
MODBUS INTERFACE MODULE  
/C02: Polyurethane coating  
27.5 [1.08]  
/C03: Rubber coating  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-8354)  
130  
[5.12]  
PACKAGE INCLUDES...  
• Terminating resistor (110 Ω, 0.25 W)  
109  
[4.29]  
mm [inch]  
GENERAL SPECIFICATIONS  
Connection  
Modbus: Euro type connector terminal  
MODEL: R3-NM1-[1][2]  
(applicable wire size: 0.2 to 2.5 mm , stripped length 7 mm)  
2
Internal bus: Via the Installation Base  
(model: R3-BSx)  
ORDERING INFORMATION  
• Code number: R3-NM1-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-NM1-R/CE/Q)  
Internal power: Via the Installation Base (model: R3-BSx)  
Power input, RUN contact output: M3 separable screw  
terminal (torque 0.5 N·m)  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
Screw terminal: Nickel-plated steel  
Isolation: Modbus to internal bus or internal power to power  
input to RUN contact output to FG  
Input error data: Input value setting at input module error  
with side DIP SW  
[1] POWER INPUT  
N: No power supply  
Main/Sub switching control in dual communication mode:  
Selectable with the side DIP SW (refer to the manual)  
Dual communication setting: Set with the side DIP switch  
Data allocation setting: Set with the side DIP switch  
RUN indicator: Bi-color (green/red) LED; Green ON in normal  
communication; Red ON when receiving data (Function  
selected with DIP SW)  
AC Power  
K3: 100 – 120 V AC  
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *  
(CE not available)  
L3: 200 – 240 V AC  
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *  
(CE not available)  
ERR indicator: Bi-color (green/red) LED; Green blinking / ON  
(0.1 sec.) at communication or setting error; Red ON at  
transmitting data (Function selected with DIP SW)  
RUN CONTACT OUTPUT  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *  
* Not selectable for use with independent power modules or  
network modules with the internal power input options.  
ON when RUN indicator is green (Modbus in normal  
communication)  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
[2] OPTIONS (multiple selections)  
Standards & Approvals  
blank: Without CE  
(Less than 50 V AC to conform with EU Directive)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
/CE: CE marking  
Other Options  
blank: none  
Mechanical life: 2 × 10 cycles (300 cycles/min.)  
7
/Q: Option other than the above (specify the specification)  
When driving an inductive load, external contact protection  
and noise quenching recommended.  
R3-NM1 SPECIFICATIONS  
ES-8354 Rev.24 Page 1/8  
https://www.m-system.co.jp/  

与R3-NM1-K3/Q相关器件

型号 品牌 描述 获取价格 数据表
R3-NM1-L3 MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格

R3-NM1-L3/CE MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格

R3-NM1-L3/Q MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格

R3-NM1-R MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格

R3-NM1-R/CE MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格

R3-NM1-R/Q MSYSTEM Remote I/O R3 Series MODBUS INTERFACE MODULE

获取价格