EUROLINE - DC/DC-Converter
RxxVxx-Series, 2 Watt, DIP24, 6kVDC Isolation (Dual Output)
Features
● 6kVDC Isolation
● Efficiency to 80%
● UL 94V-0 Package Material
● Internal SMD Construction
● MTTF up to 1.0 Million Hours
● BS EN 60950 Certified
● Fully Encapsulated
● UL1950 E196683 Recognised
Selection Guide 5V, 12V Input types
Part Number
Nom. Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
Isolation
Capacitance
(pF)
Package
Style
(%)
74
76
77
78
78
81
82
82
R05V05
R05V09
R05V12
R05V15
R12V05
R12V09
R12V12
R12V15
5
5
5
9
200
111
83
1.8
1.9
2.0
2.1
1.9
2.0
2.1
2.2
5
12
15
5
5
67
DIP24
12
12
12
12
200
111
83
9
12
15
67
Absolute Maximum Ratings
Input Voltage VIN
05V types
12V types
7VDC
15VDC
Short Circuit Duration 1)
Internal Power Dissipation
1 s
0.9W
Lead Temperature 1.5 mm from Case for 10 seconds
300°C
Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range VIN (continuous operation)
5V types
12V types
4.5VDC min. / 5.5VDC max.
10.8VDC min. / 13.2VDC max.
Output Voltage Accuracy (see tolerance envelope)
Line Regulation (highVIN to low VIN)
–7.5% min. / 10% max.
1.0% typ. / 1.0% of VIN
6% min. / 12% max.
200mVp-p max.
6000VDC min.
10 GΩ min.
Load Regulation (10% load to rated load) (depending on the type)
Output Ripple (BW=DC to 20MHz, all output types)
Isolation Voltage (flash tested for 1 second)
Resistance (Viso = 500VDC)
Switching Frequency at Full Load (depending on the type)
Package Weight
35kHz max.
7.5 g
Operating Temperature Range
0°C to +70°C
Storage Temperature Range
+50°C to +130°C
+32°C max.
Temperature Rise Above Ambient (all output types)
MTTF 2) (depending on the type)
– 0°C
+25°C
+85°C
89kHrs min. / 961kHrs max.
82kHrs min. / 747kHrs max.
62kHrs min. / 311kHrs max.
1).
2).
Supply voltage must be discontinued at the end of the short circuit duration
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
EU 36
Updated: 6. Dec. 2001
www.recom-international.com