Screwless Clamp Terminal Socket
PYFjjS
H Screwless clamping greatly contributes to
reduce wiring time
H No over or under tightening of cable
connection so better contact reliability is
achieved
H Double wiring possible on all the terminals,
and easy bridge and branch connections
H Use either solid or stranded wires from 0.2
to 1.5 mm2 (AWG24 to AWG16)
H Safe terminal arrangement: Coil terminals
separated from contact terminals
H Unique ejector enables easy relay
replacement
H Two types of nameplate are available: New
RC
MY and Legrand
H Finger-protection construction
Ordering Information
Part number
Item
4-pole
2-pole
Socket
PYF14S
PYF08S
PYCM-08S
Clip & Release lever PYCM-14S
Nameplate
R99-11 nameplate for MY
PYDM-14SR, PYDM-14SB
Socket Bridge
PYDM-08SR, PYDM-08SB
Specifications
Item
PYF14S
PYF08S
Remarks
Relay
MY2 Series
MY4 Series
MY2 Series
---
Dimensions
31 × 85 × 36.5 mm max. (W × H × D)
23.2 × 85 × 36.5 mm max. (W × H × D)
---
Rated voltage
Rated carry current
250 V AC
---
10 A at 55°C with MY2 (S) (see note)
5 A at 70°C with MY4 (S)
10 A at 55°C with MY2 (S)
7 A at 70°C with MY2 (S)
VDE0627
2
Applicable wires
0.2 to 1.5 mm (AWG24 to AWG16)
---
Solid wire
Stranded wires
Number of wire
connections
2 wires per terminal (1 wire per hole)
---
2
2
Clamping force
10 N min. (0.2 mm )
EN60999
40 N min. (1.5 mm )
Note: MY2 (S) can be used at 70°C but at 7 A.
J SAFETY STANDARDS (APPROVAL PENDING)
VDE0627 (IEC664, EN60999)
UL508 (UL1059)
CSA C22.2 No. 14 (CSA C22.2 No. 158)
1