PSPWX150 SERIES
Rev A
Wall Industries, Inc.
Up to 150 Watts, AC/DC Switching Power Supplies
Open Frame (Suffix “O”)
FEATURES
• RoHS Compliant
• Built-in Active PFC Function, PF > 0.9 at 230VAC
• Short Circuit, Over Load, and Over Temperature Protection
• MTBF > 100,000 Hours
• Dual to Quad Outputs
• High Efficiency up to 80%
• 120 Watts with Convection Cooling
• 150 Watts with Forced Air Cooling
• 90~264 VAC Input Voltage Range
• UL60950-1, CSA 22.2 No.60950-1, Nemko EN60950-1, & CB IEC60950-1
Safety Approvals
• Open Frame and U-Chassis Mechanical Options Available
Size: 5.00 x 3.00 x 1.36 inches
U-Chassis (Suffix “U”)
DESCRIPTION
The PSPWX150 series of AC/DC switching power supplies provides 120 Watts of output power with convection
cooling and 150 Watts with 30CFM forced air. This series consists of dual, triple, and quad output models with a 90-
264VAC input voltage range. These supplies also feature a high efficiency up to 80% and a power factor > 0.9 at
230VAC. These supplies are also protected against short circuit, over load, and over temperature conditions. The
PSPWX150 series has UL60950-1, CSA 22.2 No.60950-1, Nemko EN60950-1, and CB IEC60950-1 safety approvals. This
series is also CE marked and meets EN55022 Class B, CISPR22 Class B, and FCC Part 15 Class B EMC standards. Both
open frame and U-chassis mechanical options are available for this series.
Size: 5.00 x 3.17 x 1.57 inches
SPECIFICATIONS: PSPWX150 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
TEST CONDITIONS
Min
Typ
Max
Unit
90
47
264
63
VAC
Hz
115VAC and full load
230VAC and full load
115VAC, cold start, 25°C
115VAC, cold start, 25°C
115VAC and full load
230VAC and full load
2.5
1.25
40
Input Current (rms)
Inrush Current
A
A
80
0.95
0.90
Power Factor Correction
OUTPUT SPECIFICATIONS
Output Voltage
Total Regulation
See Table
See Table
120
150
See Table
Convection cooling
With 30CFM forced air
Output Power
W
Output Current
Minimum Load
See Table
Measured at 20MHz limited bandwidth and with 0.1μF ceramic and 10μF
electrolytic capacitors in parallel across the output
115VAC and full load
Ripple & Noise
See Table
Hold-up Time
PROTECTION
16
ms
Short Circuit Protection
Over Load Protection
Over Temperature Protection
GENERAL SPECIFICATIONS
Efficiency
Automatic recovery
160
Auto-recovery
Auto-recover; the temperature sensing point is located at HS1
110
84
%
°C
88
92
115VAC and full load
80
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature Range
Humidity
Derating linearly 2.5% per °C from +41°C to +60°C
0
-40
+60
+85
95
°C
°C
Non-condensing
Full load, 25°C ambient temperature
5
100,000
%
hours
MTBF
PHYSICAL SPECIFICATIONS
Open Frame Models (Suffix “O”)
U-Chassis Models (Suffix “U”)
Open Frame Models (Suffix “O”)
U-Chassis Models (Suffix “U”)
0.86 lbs (390g)
1.11 lbs (500g)
Weight
5.00 x 3.00 x 1.36 in (127 x 76.2 x 34.5 mm)
5.00 x 3.17 x 1.57 in (127 x 80.5 x 40.0 mm)
Dimensions (L x W x H)
SAFETY & EMC
Safety Approvals
EMC Standards
UL60950-1, CSA 22.2 No.60950-1, Nemko EN60950-1, CB IEC60950-1
EN55022 Class B, CISPR22 Class B, FCC Part 15 Class B, CE
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/30/2013
Page 1 of 5