Portable, Shielded SCC Module Carriers
NI SC-2345 Series, NI SC-2350
• Accept up to 20 SCC modules
• Portable, low-profile packaging
• Cable directly to an E Series or
Basic multifunction device
• Powered by DAQ device
(additional power options available)
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW™
• LabWindows™/CVI™
• Measurement Studio™
• Lookout
SC-2345 Connector Block
• Screw terminal connectivity
• VI Logger
SC-2345 with
Other Compatible Software
• Visual Basic
• C/C++, C#
Configurable Connectors
• Panelettes for sensor connectivity,
control, and display
Measurement Services Software
• NI-DAQ 7
• Blank panelettes for filler
SC-2350 with Configurable
TEDS Connectors
• Accepts up to 16 channels of
TEDS Class II smart sensors
• Panelettes for sensor connectivity
Overview
Sockets J17 through J20 access the two analog output channels and
The National Instruments SC-2345 Series consists of two types of the GPCTR channels 0 and 1.
carriers, the NI SC-2345 connector block and the SC-2345 with
configurable connectors. The SC-2350 is a similar carrier with
configurable TEDS (Transducer Electronic Data Sheet) connectors
for connecting to smart TEDS sensors. These enclosures for SCC
signal conditioning modules connect directly to 68-pin DAQ devices.
They include sockets for SCC modules, along with screw terminals
for convenient connection to digital I/O and counter/time (GPCTR)
signals from the DAQ device. These carriers offer three power
options to increase the flexibility of deployment.
SC-2345 Connector Block
The SC-2345 includes 20 SCC sockets, labeled J1 through J20 (see Figure
1). Sockets J1 through J8 accommodate SCC modules for conditioning
signals on the analog input channels of the DAQ device. For example, an
SCC module plugged into socket J1 conditions signals for channels 0 and
Figure 1. Diagram of Socket Layouts on SC-2345 Connector Block
8 of the device.
You can use sockets J9 through J16 for either digital I/O modules or
dual-stage analog input conditioning. When using dual-stage
conditioning of analog inputs (for applicable modules only in the
SC-2345 series carriers), wire your input signal to the first-stage module
(in sockets J9 through J16). The SC-2345 routes the output signal of the
first-stage SCC module to the input of the second stage SCC module
internally (see Figure 2). When using sockets J9 through J16 for digital
I/O, simply plug in a digital SCC module or the SCC-FT01 for custom
digital applications. You can use any combination of SCC digital input or
digital output modules. The digital I/O lines of E Series or Basic
multifunction DAQ devices are configurable for input and output on a
line-by-line basis. You can also access the DIO lines of the DAQ device
using the screw terminal block.
Analog SCC
Connected to J1
Second Stage
Analog SCC
Connected to J1
Inputs
First Stage
Analog SCC
Connected to J9
Signals routed to
the second stage
SCC internally
Inputs
A. Single-Stage Analog Input
SCC Configuration
B. Dual-Stage Analog Input
SCC Configuration
Figure 2. Single-Stage and Dual-Stage Analog Input SCC Configuration for the
SC-2345 Connector Block