SCXI 16-Channel RTD Module

NISCXI-1306 数据手册

 浏览型号NISCXI-1306的Datasheet PDF文件第2页浏览型号NISCXI-1306的Datasheet PDF文件第3页浏览型号NISCXI-1306的Datasheet PDF文件第4页浏览型号NISCXI-1306的Datasheet PDF文件第5页 
SCXI 16-Channel RTD Module  
NI SCXI-1503 NEW!  
• 16 channels of voltage or  
resistive inputs  
Operating Systems  
• Windows XP/2000/NT  
• Ideally suited for 2-, 3-, and 4-wire  
RTD and thermistor measurements  
• Programmable gain settings per channel  
• 5 Hz filter per channel  
Recommended Software  
• LabVIEW  
• LabWindows/CVI  
• Measurement Studio  
• 100 μA current excitation  
• 333 kS/s maximum sampling rate  
Other Compatible Software  
• NI-DAQmx driver software  
simplifies configuration, scaling,  
and measurements  
• Visual Basic, C, C++  
Measurement Services  
Software (included)  
• NI-DAQmx driver software  
• Measurement & Automation Explorer  
configuration utility  
Calibration Certificate Included  
Overview  
Current Source Operation  
The National Instruments SCXI-1503 RTD module provides 16 differential SCXI-1503 current sources continuously provide 16 channels of 100 μA  
input channels, 16 channels of 100 μA current excitation, and one  
cold-junction (CJ) sensor channel. The NI SCXI-1503 is ideally suited  
for measuring resistive transducers, such as RTDs or thermistors. Each  
channel has an amplifier with a selectable gain of 1 or 100 and a lowpass  
filter with a 5 Hz cutoff frequency to reject 50/60 Hz noise. The SCXI-1503  
can programmatically connect each input to ground, which greatly  
improves its accuracy by enabling a self-calibration of each input to  
reduce offset drift errors. You can multiplex several SCXI-1503 modules  
and other SCXI modules into a single channel on the data acquisition  
device, greatly increasing the number of analog input signals that you  
current excitation. These current sources are on whenever the SCXI  
chassis is powered on. SCXI-1503 current sources are designed to be  
accurate within 0.05 percent of the specified value with a temperature  
drift of no more than 5 ppm/ꢀC. The accuracy and stability of these  
current sources make them especially well-suited to measuring  
resistance to a high degree of accuracy.  
Calibration  
The SCXI-1503 is shipped with a calibration certificate and is calibrated  
at the factory to the specifications described in NI SCXI-1503  
can digitize. The SCXI-1306 is a front mounting terminal block that offers Specifications. Calibration constants, stored inside the calibration  
screw-terminal connectivity for the SCXI-1503.  
EEPROM, provide software correction values that your application  
development software uses to correct the measurements for both offset  
and gain errors in the module.  
Analog Input  
Each of the 16 differential analog input channels feeds to a separate  
instrumentation amplifier with a programmable gain of 1 or 100. Each  
channel has a fixed 100 μA current excitation. Then the signal passes  
through a fixed two-pole, 5 Hz lowpass filter. The CJ sensor input  
channel reads the sensor temperature from the terminal block. The  
temperature sensor is for cold-junction compensation of thermocouple  
measurements. The CJ sensor channel also passes through a 5 Hz  
lowpass filter to reject unwanted noise on the SCXI-1503. Along with  
the other 16 input channels, the CJ sensor is multiplexed to the output  
buffer, where the data acquisition device can read it.  
Measurement Services Software  
NI-DAQmx measurement services software is included with all  
National Instruments data acquisition and signal conditioning products.  
This easy-to-use software tightly integrates the full functionality of your  
NI data acquisition hardware with NI LabVIEW, LabWindows/CVI, and  
Measurement Studio for Visual Basic software. High-performance  
features include multidevice synchronization, networked measurements,  
and DMA data management. Bundled with NI-DAQmx, the Measurement  
& Automation Explorer (MAX) utility simplifies the configuration of your  
measurement hardware with device test panels, interactive  

与NISCXI-1306相关器件

型号 品牌 获取价格 描述 数据表
NISCXI-1503 NI

获取价格

SCXI 16-Channel RTD Module
NISCXI1521 NI

获取价格

SCXI Quarter-Bridge Strain Gage Input Module
NISCXI-1521 NI

获取价格

SCXI Quarter-Bridge Strain Gage Input Module
NISCXI-1521B NI

获取价格

24 quarter-bridge strain gage inputs/Programmable excitation
NISR10JTR NICHICON

获取价格

General Purpose Inductor, 0.1uH, 5%, 1 Element, Alumina-Core, SMD
NIT10 ETC

获取价格

************GESTRICHEN************
NIT16 ETC

获取价格

*****GESTRICHEN*****
NIT2 ETC

获取价格

************GESTRICHEN************
NITAI100V0.47UF ETC

获取价格

CAPACITOR N/P 0.47UF 100V
NITAI100V1.0UF ETC

获取价格

CAPACITOR N/P 1.0UF 100V