VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
For main and standby power supplies.
LC-R121R3P
Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
Dimensions (mm)
Terminal type: Faston 187
1.870+ 0.039 (47.5 1)
+
3.819 + 0.039 (97 +1)
-
-
-
-
1.213 (30.8)
1.85 (47)
3.799 (96.5)
Battery case resin: Standard (UL94HB) Color is black.
Photo/Label for reference only.
Discharge characteristics 77°F (25°C) (Note)
Specifications
14.4
13.8
13.2
12.6
12.0
11.4
10.8
10.2
9.6
9.0
8.4
7.8
Nominal Voltage
12V
1.3Ah
Rated Capacity (20 hour rate)
Length
3.819 inches (97.0 mm)
Width
1.870 inches (47.5 mm)
1.969 inches (50.0 mm)
Dimensions
Height
Total Height
Approx. mass
0.065A
0.13A
0.26A
2.165 inches (55.0 mm)
1.30 lbs. (0.59 kg)
1.3A
Standard Terminals
and Resin
UL94HB Faston 187
LC-R121R3P
0
1
2
4
6 8 10 20 40 60
(Minute)
2
4
6 8 10 20 40
(Hour)
Duration of discharge
Characteristics
(Note)
20 hour rate (65mA)
1.3Ah
1.2Ah
1.05Ah
0.85Ah
Duration of discharge vs. Discharge current
10 hour rate (120mA)
5 hour rate (210mA)
1 hour rate (850mA)
Capacity (note)
77˚F (25˚C)
30
20
15
1.5 hour rate discharge
Cut-off voltage 10.5 V
Fully charged battery
77˚F (25˚C)
0.6A
10
Approx. 90mΩ
Internal Resistance
5
4
3
Temperature
dependency
of capacity
102%
100%
85%
104˚F (40˚C)
77˚F (25˚C)
32˚F (0˚C)
(20 hour rate)
65%
5˚F (-15˚C)
2
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
1.5
91%
82%
64%
104˚F (40˚C)
77˚F (25˚C)
1
50
40
Self discharge
77˚F (25˚C)
30
20
32˚F (0˚C)
Cycle use
Initial current
0.52 A or smaller
(Repeating
use)
Charge
Method
(Constant
Voltage)
10
14.5V to 14.9V
(per 12V cell 25˚C)
5˚F (-15˚C)
Control voltage
Initial current
5
3
0.195 A or smaller
Trickle use
13.6V to 13.8V
(per 12V cell 25˚C)
Control voltage
30
50
100
300 500
1
3
5
10
(mA)
Discharge current
(A)
(Note) The above characteristics data are average values obtained
within three charge/discharge. Cycles not the minimum values.
VRLA BATTERIES
NOVEMBER 2002
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.