5秒后页面跳转
LCR-8110G PDF预览

LCR-8110G

更新时间: 2024-11-06 01:08:59
品牌 Logo 应用领域
固纬 - GWINSTEK /
页数 文件大小 规格书
2页 703K
描述
10MHz / 5MHz / 1MHz PRECISION LCR METER

LCR-8110G 数据手册

 浏览型号LCR-8110G的Datasheet PDF文件第2页 
10MHz / 5MHz / 1MHz PRECISION LCR METER  
LCR-8000G Series  
FEATURES  
Wide Test Frequency 20Hz~10/5/1MHz  
0.1% Basic Accuracy & 6 Digits  
Measurement Resolution  
Large LCD Display with Intuitive User  
Interface  
Full Measuring Functions with DUT V/I  
Monitor  
PASS/FAIL Function ( abs , % ,  
with Judgment Alarm  
)
The Smarter Way to Characterize Components  
The LCR-8000G Series LCR meter, with test frequency up to 10MHz, provides accuracy, versatility and high  
resolution for a wide range of component measurements, even including DC resistance measurement and  
Voltage/Current monitoring. The Multi-Step function allows on-screen programming of customized  
measurement sequence with Pass/Fail indication. Each program includes 30 test steps and each test step can be  
set with selected parameters and test limits. Under Multi-Step operation, a tedious work routine can be done  
step by step automatically just at a press of a button. With Graph Mode, LCR-8110G, LCR-8105G and LCR-8101G  
display the component impedance response either over a wide range of test frequency sweep or over a wide  
range of test voltage sweep in a graph chart. This gives an analysis result of either impedance vs. frequency or  
impedance vs. applied voltage all at a glance. GPIB and RS-232C interfaces are available as standard for  
instrument control and test result display on the PC. The rich features of LCR-8000G Series easily make your  
measurement tasks done at a very competitive price.  
Average 1 ~ 256 Times  
DC Resistance Measurement  
Multi Step Mode  
Graph Mode  
Standard RS-232C / GPIB Interface  
Wide Frequency Range With Friendly  
Intuitive User Interface  
Graph Mode  
The graph function shows the component  
characteristics in visual manner. Either voltage sweep  
or frequency sweep can be selected for horizontal  
scale. Just select the parameter, and set the start/stop  
The LCR-8000G Series is designed to perform precision  
impedance measurements over a wide frequency range  
of 20Hz ~ 10MHz for LCR-8110G, 20Hz ~ 5MHz for  
LCR-8105G and 20Hz ~1MHz for LCR-8101G. The  
instrument is capable of measuring 11 different  
parameters with 0.1% basic accuracy, which meets the  
precision measurement requirements of components  
and modules used in the RF circuits. The large LCD  
display with single-layer operation menu of LCR-8000G  
Series provides users with ultimate convenience to  
plug and play without much learning time.  
Cvo.ltage or the start/stop frequency of the sweep, LCR  
-8000G will run through the sequence of  
measurements and show the results on a graph.  
This graphical parameter measurement performs the  
characteristic verification of components and  
materials over the response to the changes in AC test  
frequency or AC test voltage without the need of  
complex programming of an external controller. When  
the graph gets out of the vertical range, the LCR-  
8000G Series can automatically adjust the scale to  
get full test information. On the graph the marker  
operation is available for detailed observation.  
Multi Step Mode  
Pass/fail Function With Judgment Alarm  
The Multi-Step mode is capable of running a series of  
measurements of a component at a number of user-  
defined steps in sequence automatically. Total 64  
programs can be saved into the non-volatile memory,  
and each program contains up to 30 test steps. The  
parameter and Hi/Lo limits can be set respectively for  
each test step. After a program being properly edited,  
the instrument can run through all the measurement  
steps either at a press of the button under the Manual  
Trigger selection, or automatically run the program by  
detecting the connection of a DUT under the Auto  
Trigger selection. When all the test steps are  
In the Pass/Fail test, primary parameter measurement  
result is compared with user-defined limits and the  
pass or fail result is then displayed. Three methods,  
including absolute limit, percentage and delta limit,  
are available for Hi(high) and Lo(low) limit setting  
based on the nominal test value. The Pass/Fail test  
checks whether the parameter measurement result  
sits within the limits, then display "PASS" for within  
the limits, or "LO" for lower than the low limit, or  
"HI" For higher than the high limit. A scale and bar  
for displaying measurement result is shown at the  
center of the screen to give a graphical identification,  
which greatly reduces operator's load in a long time  
inspection work. This scale and bar also facilitate the  
adjustment of the variable components. Either Pass  
or Fail result can be set with a buzzer alarm, which  
makes component or material sorting easy with  
sound identification.  
APPLICATIONS  
Education Lab and Training Institution  
Research & Design  
Quality Assurance Verification  
completed, the screen shows the measurement  
reading of the parameter being selected for each step  
with Pass, HI, or LO measurement result.  
C.  
LCR-8000G Series  
Simply Reliable  

与LCR-8110G相关器件

型号 品牌 获取价格 描述 数据表
LCR-8200 GWINSTEK

获取价格

High Frequency LCR Meter
LCR-8205 GWINSTEK

获取价格

High Frequency LCR Meter
LCR-8210 GWINSTEK

获取价格

High Frequency LCR Meter
LCR-8220 GWINSTEK

获取价格

High Frequency LCR Meter
LCR-8230 GWINSTEK

获取价格

High Frequency LCR Meter
LC-RA1212 PANASONIC

获取价格

For main and standby power supplies.
LC-RA1212P PANASONIC

获取价格

VALVE-REGULATED LEAD ACID BATTERIES:
LC-RD1217P PANASONIC

获取价格

VALVE-REGULATED LEAD ACID BATTERIES:
LCR-H02004DSF LUMEX

获取价格

20 x 4 CHARACTER LCD MODULE, STN YELLOW, TRANSFLECTIVE, LED BACKLIGHT
LCR-H02004DSF-Q-Y LUMEX

获取价格

20 X 4 Character LCD MODULE