Current Transducer LA 25-NP/SP14
IPN = 0.25 A
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
16094
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
0.25
0 .. ± 0.36
RM min
A
A
Features
· Closed loop (compensated) multi-
turns current transducer using the
Hall effect
· Printed circuit board mounting
· Insulated plastic case recognized
according to UL 94-V0.
RM max
with ± 15 V
@ ± 0.25 A max
@ ± 0.36 A max
100
100
320
190
W
W
ISN
KN
VC
IC
Vd
Vb
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
25
mA
100 : 1000
± 15
10 + IS
2.5
600
1700
V
mA
kV
V
Current consumption
Special features
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
R.m.s. rated voltage 1), safe separation
basic isolation
· IPN = 0.25 A
· IP = 0 .. ± 0.36 A
· KN = 100 : 1000
· TA = - 10°C .. + 70°C.
V
Accuracy - Dynamic performance data
Advantages
X
e
Typical accuracy @ IPN , TA = 25°C
Linearity error
± 0.5
< 0.2
%
%
L
· Excellent accuracy
· Very good linearity
Typ Max
± 0.05 ± 0.15 mA
IO
IOM
IOT
Offset current2) @ IP = 0, TA = 25°C
Residual current3) @ IP = 0, after an overload of 3 x IPN ± 0.05 ± 0.15 mA
Thermal drift of IO
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
- 10°C .. + 70°C
± 0.10 ± 0.35 mA
tr
f
Response time 4) @ 90 % of IPN
Frequency bandwidth (- 1 dB)
< 1
DC .. 150
µs
kHz
· Current overload capability.
General data
Applications
TA
TS
Ambient operating temperature
Ambient storage temperature
- 10 .. + 70
- 25 .. + 85
< 860
110
496
°C
°C
mW
W
µH
MW
g
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
RP
RS
L P
RIS
m
Primary coil resistance @ TA = 25°C
Secondary coil resistance @ TA = 70°C
Primary insertion inductance
Isolation resistance @ 500 V, TA = 25°C
Mass
> 1500
22
Standards
EN 50178 : 1997
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications.
1)
Notes : Pollution class 2
2)
Measurement carried out after 15 mn functioning
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
3)
4)
060405/4
LEM
www.lem.com