COUNT
2
DESCRIPTION OF REVISIONS
RE-5-2935
DATE
K.C.J A.B.H 23.01.11
COUNT
DESCRIPTION OF REVISIONS
DATE
BY CHKD
BY CHKD
△
△
1
△
APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-40℃ ~ 85℃ (NOTE1)
-10℃ TO 60℃(WITH PACKING)
TEMPERATURE RANGE
VOLTAGE
1
1
RATING
AC 10V
0.5A
OPERATING OR
STORAGE HUMIDITY RANGE
95% MAXIMUM
(NON-CONDENSING)
CURRENT
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT
ACCORDING TO DRAWING
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
IEC60512-2-1
OPEN VOLTAGE 20 mV AC MAX
INITIALLY 100mΩ MAXIMUM (NOTE2)
INITIALLY 1000MΩ MINIMUM
X
-
TEST CURRENT 1mA
INSULATION RESISTANCE MEASURE WITHIN 1 MINUTE AFTER APPLYING
X
X
-
X
IEC60512-3-1
500V DC
VOLTAGE PROOF
IEC60512-4-1
① NO FLASHOVER OR BREAKDOWN
② CURRENT LEAKAGE 1mA MAXIMUM
500Vrms AC IS APPLIED FOR 1 MINUTE
MECHANICAL CHARACTERISTICS
5,000 TIMES INSERTION AND WITHDRAWAL
SHALL BE MADE AT THE CYCLE RATE LESS
THAN 10 CYCLES PER 1MINUTE (WITH NOR
CARD)
NOTE : AFTER EACH 10 CYCLES STOP THE
INSERTION AND REST THE CONNECTOR
FOR 5 TO 10 MINUTES.
① CONTACT RESISTANCE:
MECHANICAL OPERATION
[OFFICE ENVIRONMENT]
EIA364B class 1.1
AFTER TEST 50mΩ MAXIMUM CHANGE
X
-
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
CARD SURFACE SHALL BE CLEANED BY AIR
BLOW:
AT EACH 100 CYCLES INTERVAL(10 TIMES)
FROM START TO 1,000 CYCLES.
AT EACH 1,000 CYCLES INTERVAL(4 TIMES)
FROM 1,001 CYCLES TO 5,000CYCLES.
① NO ELECTRICAL DISCONTINUITY OF 1us
VIBRATION AND HIGH
FREQUENCY
IEC60512-6-4
FREQUENCY 10 TO 55 TO 10 Hz/min, SINGLE
AMPLITUDE 0.75mm FOR 4h IN X,Y,Z 3
DIRECTIONS, TOTAL 12h
X
X
-
-
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
ACCELERATION 490m/s2 STANDARD HOLDING
TIME 11ms, SEMI-SINE WAVE FOR 3 TIMES IN 3
DIRECTIONS, TOTAL 18 TIMES.
SHOCK
IEC60512-6-3
③ CONTACT RESISTANCE
AFTER TEST 50mΩ MAXIMUM CHANGE
REFERENCE DRAWING
REMARKS
DRAWN
DESIGNED
CHECKED
APPROVED
RELEASED
(NOTE1) : INCLUDE THE TEMPERATURE RISE BY CURRENT
ENG
(NOTE2) : CONTACT RESISTANCE INCLUDES CONDUCTOR RESISTANCE UNLESS
OTHERWISE SPECIFIED. THE TEST SHOULD BE DONE UNDER TEMP 15 TO 35℃.
AIR PRESSURE 86 TO 106kPA, RESLATIVE HUMIDITY 25 TO 85%.
(NOTE3) : IT MAY BE CHANGED ACCORDING TO THE TRAY/CARD MATERIAL AND
DIMENSIONS.
W.H.LEE
19.06.27
W.H.LEE
19.06.27
W.S.YOON
19.06.27
B.H.AN
19.06.27
23.01.11
DEPT
(NOTE4) : DON'T USE CUTTING CARD FROM MICROSIM OR MINI SIM CARD BY MANUAL.
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST X: APPLICABLE TEST
PART NO.
HIROSE KOREA CO.,LTD.
CODE NO.(OLD) DRAWING NO.
CL ELC4-632697
SPECIFICATION SHEET
KP13TJ-SF SIM BLOCK(800)
1
CODE NO.
2
CL 6530-0018-9-800