NEMIC-LAMBDA
JWS 50
SPECIFICATIONS
A157-01-01A
MODEL
JWS50
-3
JWS50
-5
JWS50
-12
JWS50
-15
JWS50
-24
JWS50
-48
ITEMS
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
V
A
W
3.3
10
33
5
10
50
74
12
4.3
51.6
76
15
3.5
52.5
77
24
2.2
52.8
79
48
1.1
52.8
79
(*1) %
65
5 Input Voltage Range
6 Input Current (100/200VAC)(Typ) (*1) A
(*2)
-
85 - 265VAC (47-63Hz) or 120 - 330VDC
0.8/0.4
0.6/0.3
7 Inrush Current(Typ)
8 PFHC
-
-
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet EN61000-3-2
9 Power Factor (100/200VAC)(Typ) (*1) -
0.99/0.95
10 Output Voltage Range
11 Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Temperature Coefficient
15 Over Current Protection
16 Over Voltage Protection
17 Hold-up Time (Typ)
18 Leakage Current
19 Remote Sensing
20 Parallel Operation
21 Series Operation
22 Operating Temperature
23 Operating Humidity
24 Storage Temperature
25 Storage Humidity
V
2.85-3.63
120
4.5-5.5
120
160
20
10.8-13.2 13.5-16.5 21.6-26.4 43.2-52.8
150
180
48
150
180
60
150
180
96
200
240
192
240
160
20
40
(*4) mV
(*5) mV
40
96
120
150
Less than 0.02%/°C
4.5 ~ 3.6 ~
(*6) A
10.5 ~
10.5 ~
2.3 ~
1.15 ~
(*7)
(*8)
(*9)
-
-
-
-
-
-
-
-
-
-
-
-
3.79-4.95 5.75-6.75 13.8-16.2 17.3-20.3 27.6-32.4 55.2-64.8
20ms
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
-
-
Possible
(*10)
-10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%)
30 ~ 90%RH (No dewdrop)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
26 Cooling
27 Withstand Voltage
Convection Cooling
Input - FG : 2KVAC (20mA), Input - Output : 3KVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100Mohm at 25°C and 70%RH Output - FG... 500VDC
At no operating, 10-55Hz (Sweep for 1min)
19.6m/s2 Constant, X,Y,Z 1hour each.
Less than 196.1m/s2
28 Isolation Resistance
29 Vibration
-
-
30 Shock (In package)
31 Safety
-
-
(*11)
Approved by UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI
32 Conducted Emission
33 Radiated Emission
34 Weight(Typ.)
-
-
g
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
350
35 Size (WxHxD)
mm
37 x 85 x 159 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100-240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 - 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A157-01-02_).
*11. As for DENTORI, built to meet at 100VAC.