描述
40 Watts JCK Series

JCK4048S3V3 数据手册

 浏览型号JCK4048S3V3的Datasheet PDF文件第2页 
xppower.com  
40 Watts  
JCK Series  
2:1 Input Range  
Very High Power Density  
Single and Dual Outputs  
High Efficiency ꢀ Up to 92%  
Remote On/Off  
1600 VDC Isolation  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage Range  
• 12 V (9-18 VDC),  
24 V (18-36 VDC),  
48 V (36-75 VDC)  
Efficiency  
Isolation  
• See table  
• 1600 VDC Input to Output  
1600 VDC Input to Case  
1600 VDC Output to Case  
Input Current  
• See table  
Input Reflected  
Ripple Current  
• 20 mA pk-pk through 12 µH inductor,  
5 Hz to 20 MHz  
Isolation Capacitance • 1000 pF typical  
Switching Frequency  
Power Density  
MTBF  
• 270 kHz typical  
• 50 W/in  
• 330 kHrs min to MIL-HDBK-217F  
at 25 ˚C, GB  
3
Undervoltage Lockout • 12 V models: ON 8.6 V, OFF 7.9 V typical  
24 V models: ON 17.8 V, OFF 16 V typical  
48 V models: ON 33.5 V, OFF 30.5 V typical  
Input Surge  
• 12 V models 25 VDC for 1000 ms  
24 V models 50 VDC for 1000 ms  
48 V models 100 VDC for 1000 ms  
Environmental  
Operating Temperature • -40 ˚C to +70` ˚C, derate from 100ꢀ load  
at 55 °C to 60ꢀ load at 70 °C  
• +105 ˚C max  
• Convection-cooled  
• 5-95ꢀ RH, non-condensing  
Output  
Case Temperature  
Cooling  
Output Voltage  
• See table  
Output Voltage Trim  
10ꢀ on single outputs models only,  
contact sales for details  
Operating Humidity  
Storage Temperature • -40 ˚C to +125 ˚C  
Minimum Load  
Line Regulation  
Load Regulation  
• No minimum load required  
0.5ꢀ max  
EMC  
• Single output models: 0.5ꢀ max  
Dual output models: 1ꢀ max  
balanced outputs  
Emissions  
• EN55022 class B conducted & radiated  
with external components, see application  
note  
• EN61000-4-2, 4 kV contact discharge,  
Perf Criteria B  
• EN61000-4-3, 3 V/m, Perf Criteria A  
• EN61000-4-4, level 1, Perf Criteria A*  
• EN61000-4-5, level 1, Perf Criteria A  
• EN61000-4-6, 3 Vrms, Perf Criteria A  
• EN61000-4-8, 1 A/m, Perf Criteria A  
Cross Regulation  
Setpoint Accuracy  
Start Up Time  
5ꢀ (see note 2)  
1ꢀ  
ESD Immunity  
• 30 ms typical  
• 100 mV for 3V3 +5 V models,  
150 mV for other models (see note 3)  
• 3ꢀ max deviation, recovery to within  
1ꢀ in <250 µs for a 25ꢀ load change  
• 0.02ꢀ/˚C  
Radiated Immunity  
EFT/Burst  
Ripple & Noise  
Transient Response  
Surge  
Conducted Immunity  
Magentic Field  
Temperature  
Coefficient  
Overvoltage Protection • 3.3 V models: 3.9 V typical  
5 V models: 6.2 V typical  
*External input capacitor required, 220 µF/100 V.  
12 V models: 15 V typical  
15 V models: 18 V typical  
12 V models: 15 V typical  
15 V models: 18 V typical  
Overload Protection  
• 115-130ꢀ of output current  
Short Circuit Protection • Trip & restart (Hiccup mode),  
auto recovery  
Remote On/Off  
• On = Logic High (>3.0) or Open  
Off = Logic Low (<1.2 V) or short pin 2  
to 3  

与JCK4048S3V3相关器件

型号 品牌 获取价格 描述 数据表
JCK-4R ETC

获取价格

Fuse
JCK50 XPPOWER

获取价格

DC-DC Converter
JCK5012S05 XPPOWER

获取价格

DC-DC Converter
JCK5012S12 XPPOWER

获取价格

DC-DC Regulated Power Supply Module,
JCK5012S15 XPPOWER

获取价格

DC-DC Converter
JCK5012S3V3 XPPOWER

获取价格

DC-DC Converter
JCK5024S05 XPPOWER

获取价格

DC-DC Regulated Power Supply Module,
JCK5024S12 XPPOWER

获取价格

DC-DC Converter
JCK5024S15 XPPOWER

获取价格

DC-DC Regulated Power Supply Module,
JCK5024S3V3 XPPOWER

获取价格

DC-DC Regulated Power Supply Module,