60W Isolated Triple Output Switching Power Supply
IT-60 series
Features :
Isolated output & GND for CH1,CH2,CH3
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 67KHz
2 years warranty
SPECIFICATION
MODEL
IT-60D
IT-60F
OUTPUT
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
5V
12V
24V
5V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
3A
0.8A
1.4A
3A
0.8A
1.3A
0.5 ~ 3A
58.2W
0.1 ~ 1A
0.2 ~ 2A
0.5 ~ 3A
58.2W
0.1 ~ 1A
0.2 ~ 2A
PEAK LOAD (3sec.)
Note.4 70W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
120mVp-p
240mVp-p
80mVp-p
CH1 : 4.75 ~ 5.5V
3.0%
150mVp-p
240mVp-p
CH1 : 4.75 ~ 5.5V
8.0%
2.0%
5.0%
8.0%
2.0%
5.0%
8.0%
2.0%
5.0%
8.0%
2.0%
5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
1.0%
2.0%
2.0%
300ms, 20ms/230VAC
800ms, 20ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
80ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
76%
18ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
1.8A/115VAC
0.9A/230VAC
COLD START 20A/115VAC
<1mA / 240VAC
40A/230VAC
72 ~ 90W rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, light industry level, criteria A
EMS IMMUNITY
MTBF
314.3K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.51Kg; 24pcs/13.2Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:IT-60-SPEC 2010-10-18