10W Output Switching Power Supply
IRM-10 series
■
‧
‧
‧
‧
‧ Ⅱ
‧
‧
‧
‧
Bauart gepr uf t
Sicherheit
egelma ge
od
o
s
be wac
g
www.tuv .com
ID 2000000000
SPECIFICATION
IRM-10-3.3
IRM-10-5
IRM-10-12
IRM-10-15
IRM-10-24
MODEL
DC VOLTAGE
3.3V
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
2.5A
2A
0.85A
0.67A
0.42A
0 ~ 2.5A
8.25W
0 ~ 2A
10W
0 ~ 0.85A
10.2W
240mVp-p
±2.0%
0 ~ 0.67A
10.05W
300mVp-p
±2.0%
0 ~ 0.42A
10.08W
480mVp-p
±2.0%
RIPPLE & NOISE (max.) Note.2 200mVp-p
200mVp-p
±2.0%
±0.3%
±0.5%
OUTPUT
Note.3
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±2.0%
±0.3%
±0.3%
±0.5%
±0.3%
±0.3%
±0.5%
±0.5%
±0.5%
600ms, 20ms/230VAC
1000ms, 20ms/115VAC at full load
30ms/230VAC
85 ~ 264VAC
47 ~ 440Hz
74%
8ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
78%
82%
82%
82%
INPUT
0.25A/115VAC
0.15A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 10A/115VAC
< 0.75mA/240VAC
20A/230VAC
115%~150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.8 ~ 16.2V 17.25 ~ 20.25V
PROTECTION
27.6 ~ 32.4V
3.8 ~ 4.95V
5.75 ~ 6.75V
OVER VOLTAGE
Protection type : Shut off o/p voltage, clamping by zener diode
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
EMC
(Note 4)
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A
Khrs min. MIL-HDBK-217F (25℃)
45.5*25.4*21.5mm (L*W*H)
OTHERS
NOTE
DIMENSION
Kg; pcs/Kg/CUFT
PACKING
℃
File Name:IRM-10-SPEC 2013-03-11