HMC4069LP4E
v02.0316
2.9 GHz INTEGER-N SYNTHESIZER
(N = 2 - 32)
Typical PLL Performance, Vcc = 5.00V
REF = 100MHz Square Wave
PFD Outputs ND, NU, LD, Vcc = 5.00V
Forced PFD Difference ≈ 11Hz
VCO = 10GHz, N = 100, T = +25C
-90
High-Z Scope, BW = 20MHz, T = +25C
5.0
-95
4.0
3.0
2.0
1.0
0.0
-100
-105
-110
-115
-120
-125
-130
-135
-140
102
103
104
OFFSET FREQUENCY (Hz)
105
106
107
-20
0
20 40 60 80 100 120 140 160 180 200
Time (mSec)
ND
NU
LD
-10dBm
-5dBm
0dBm
5dBm
Typical Supply Current vs. Vcc
Typical ND & NU Voltages, Vcc = +5V
Vcc (Vdc)
4.75
Icc (mA)
279
+25C
Symbol
Characteristics
Units
Min.
4.9
Typ.
5.0
Max.
5.1
5.00
300
Output High
Voltage
Voh
Vol
V
V
5.25
324
Output Low
Voltage
2.9
3
3.1
Reliability Information
Programming Truth Table
Junction Temperature To Maintain
1 Million Hour MTTF
(LSB)
A0
Function
A1
A2
A3
A4
135 °C
Output Low
0
0
0
1
1
-
0
0
0
0
-
0
0
0
0
-
0
0
0
0
-
Nominal Junction Temperature
(T = +85 °C)
99.3 °C
/ 2
/ 3
/ 4
-
1
Thermal Resistance
(junction to ground paddle)
0
9.5 °C/W
1
Operating Temperature
-40 to +85 °C
-
/ 32
1
1
1
1
1
Absolute Maximum Ratings
RF Input (Vcc= +5V)
+13 dBm
Supply Voltage (Vcc)
Logic Inputs (INV, A0 - A4)
PFD Outputs (ND, NU)
Storage Temperature
ESD Sensitivity (HBM)
ESD Sensitivity (CDM)
+5.5V
-0.5 to (0.5V + Vcc)
2.5 to (0.5V + Vcc)
-65 to +150 °C
Class 1B
ELECTROSTATIC SENSITIVE DEVICE
OBSERVE HANDLING PRECAUTIONS
Class C2
Notes:
1. All data shown is typical and actual performance may vary depending upon implementation.
2. Phase Noise data taken utilizing 2-unit cancellation method with VCO ≥ 2400MHz and healthy power level.
3. Only one PFD output will be active with a forced frequency difference, depending upon which input frequency is higher.
4. Without oscilloscope bandwidth limiting, there will be narrow pulses on NU, ND, & LD, at the input frequencies.
These pulses may create spectral content, which is normally surpressed with the loop filter and lock detect filter.
For price, delivery, and to place orders: Analog Devices, Inc., One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
6
Application Support: Phone: 1-800-ANALOG-D