5秒后页面跳转
GPM140 PDF预览

GPM140

更新时间: 2024-11-18 12:25:31
品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
2页 269K
描述
140 Watt Global Performance Switchers

GPM140 数据手册

 浏览型号GPM140的Datasheet PDF文件第2页 
GPC140 Commercial/GPM140 Medical  
140 Watt Global Performance Switchers  
FEATURES:  
Wide-range ac input 85-264 Vac  
2-year warranty  
Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
Single outputs  
Commercial Approved to UL1950, IEC950,  
EN60950 and CSA22.2-234 L3  
Medical Approved to UL2601-1, IEC601-1 and  
CSA22.2 No. 601  
marked to LVD  
SPECIFICATIONS:  
Output Noise  
Ac Input  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential  
mode. Measured with noise probe directly across output  
terminals of the power supply.  
85-264 Vac, 47-63 Hz single phase.  
Input Current  
Maximum input current at 120 Vac, 60 Hz with full rated  
output load: 3.7 A  
Transient Response  
Main output500 µs typical response time for return to  
within 0.5% of final value for a 50% load step change. i/  
t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/  
shutdown overshoot less than 3%.  
Hold-UpTime  
20ms minimum from loss of ac input at full load, nominal  
line (115 Vac).  
Remote Sense  
Output Power  
Provided as a standard feature.  
140 W convection; 160 W with air flow. Peak ratings are  
for 60 s maximum duration, 10% duty cycle.  
Voltage Adjustment  
Built-in potentiometer adjusts voltage ±5%.  
Overload Protection  
Fully protected against short circuit and output overload.  
Short circuit protection is cycling type power limit on  
output 1. Recovery after fault is automatic.  
Overload Protection  
Factory set to begin power limiting at approximately 175 W.  
EMI/EMC Compliance  
Overvoltage Protection  
All models include built-in EMI filtering to meet the  
following emissions requirements:  
Main outputs: 130% ± 15% typical.  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Efficiency  
Conducted Emissions GPC140 EN55022 Class B; FCC Class B  
Conducted Emissions GPM140 EN55011 Class B; FCC Class B  
70% at full rated load, nominal input voltage, depending  
on model and load distribution.  
Static Discharge  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Input Protection  
Internal ac fuse provided. Designed to blow only if a  
catastrophic failure occurs in the unit.  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
Inrush Current  
Commercial Leakage Current  
0.95 mA 254 Vac @ 60 Hz input.  
Inrush is limited by internal thermistors. Inrush at 240 Vac,  
averaged over the first ac half-cycle under cold start  
conditions will not exceed 60 A.  
Commercial Safety  
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950  
and EN60950. UL file #E135803 commercial; CSA  
#LR46516 all models. The output(s) are intended for  
safety earthed Signal Output and Intermediate Circuits  
only. All dc outputs are SELV under normal and single  
fault conditions.  
Temperature Coefficient  
0.03%/°C typical on all outputs.  
Thermal Shutdown  
Provided as a standard feature. Designed to protect unit  
from prolonged overtemperature.  
Medical Leakage Current  
60 µA 254 Vac @ 60 Hz input.  
Environmental  
Designed for 0 to 50°C operation at full rated output  
power; derate output current and total output power by  
2.5% per °C above 50°C. See Environmental and  
Packaging Specifications on next page.  
Medical Safety  
Approved to UL2601, CSA22.2 No. 601 Level 3 and  
IEC601. UL file E116994; CSA #LR46516. The output(s)  
are intended for safety earthed Signal Output and  
Intermediate Circuits only. The output(s) are not accept-  
able for patient connection without additional isolation. All  
dc outputs are SELV under normal and single fault  
conditions.  
Power Fail  
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms  
before output voltage drops more than 4% below  
nominal voltage upon loss of ac power. The signal is  
factory set to trip on 84 to 94 Vac brown-out depending  
upon incoming line impedance and distortion. Other  
settings are available to the user through adjustment of  
built-in potentiometer.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
56  

与GPM140相关器件

型号 品牌 获取价格 描述 数据表
GPM140-12 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM140-15 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM140-24 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM140-28 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM140-5 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM200 SLPOWER

获取价格

Maximum Continuous Output Power at 50°C With
GPM200A SLPOWER

获取价格

Power Supply Module
GPM200B SLPOWER

获取价格

200 Watt Global Performance Switchers
GPM200D SLPOWER

获取价格

Power Supply Module
GPM200DG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 200W